Applies To Product(s): Bentley Class Editor Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Class Editor Subarea: Schema Opening Original Author: Deepak Singh, Bentley Product Advantage Group Overview While opening OpenPlant_3D schema using Bentley Class Editor, software asks for missing reference schema files. Problem Description When opening OpenPlant_3D.01.07. ecschema (SS6) software shows missing reference as Integratedstructuralmodel.04.00. ecschema & Designsync.01.01. ecschema. The OpenPlant_3D ecschema contains the data model properties and is referenced by all OpenPlant Modeler schema Steps to Resolve Launch Bentley Class Editor . Launch Class Editor from desktop icon or launch from All programs>Bentley>Class Editor. The interface will be as shown below. Click on Open. Select your particular project, from following location select OpenPlant_3D ecschema . C:\ProgramData\Bentley\OpenPlantModelerV8i\WorkSpace\Projects\OPModeler_Imperial\DataSet\Schemas Clicking on Open will ask for locate missing reference OpenPlant schema file as shown. From below mentioned location locate above mentioned missing reference schema file. C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\OPModeler\schemas Select OpenPlant schema and click on Open. Again, it will ask to locate missing reference of Integratedstructuralmodel ecschema . From the same mentioned location select Integratedstructuralmodel ecschema and open. In the last, it will ask for locate missing reference of DesignSync ecschema as shown. From the same mentioned location, select the missing DesignSync schema and click open. This will open OpenPlant_3D schema successfully. Notice the message in bottom pane of class editor OpenPlant_3D opened successfully. It is always a good practice to set location for picking reference schemas. From class editor interface. Click on Tools > Options. In Options window, add the following path from mentioned location. For OPModeler schema : C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\OPModeler\schemas For Project Schema: C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\OPModeler_Imperial\DataSet\Schemas After adding the path for missing reference, click on Apply and OK. Still a Problem? If above problem still persist, then please create a Service Request and contact Bentley Product Advantage group along with the list of all relevant details to get in depth analysis and for possible solution or workarounds. See Also Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧