When placing Vic coupling, ie, Vic Coupling Rigid 07, in different way, it shows and differently in OPIM ISO op 1 - place a vic pipe, place a rigid 07 coupling, place another vic pipe - vic coupling class is AT_COUP_RIGID07 op 2 (most people will do) - place a vic pipe, place another vic pie, select rigid 07 from popup fastener selection - vic coupling class become AT_COUP_RIGID07_FAST Inside model, they display same and have same spec data. However, when run generating ISO via OPIM, these two coupling fall in two different OPIM classes, one goes to PIPE COUPLING and another one goes to FASTENER. And this results to that symbol and dimension are different between them. Coupling in op 1 will have a box like symbol and dimensioned on gaps. In the meantime coupling in op 2 have a clamp like symbol and with no dimensioned. I attempted to merge to class together. And all kind of error appears. I tried to move AT_COUP_RIGID07_FAST to PIPE COUPLINE class and OPIM gave me an error says "Element JOINT_HAS FASTENER is missing required attribute 'targetClass'". This is failing approach, so I tried to add a extra calculated port for it, OPIM keep generating iso and hang. and then I tried to remove calculation port (pipe coupling does not have calculated port property), and error "Index was outside the bounds of the array" How can I merge this two classes together? My main purpose is to dimension coupling gap. Thanks, Maggie
↧