Forum Post: RE: JOINING PIPES AT AN ANGLE WITHOUT ANGLE at a certain angle (let's say to 20 degrees)

$
0
0
Hello Stefan, Use variable OPM_ALIGNMENT_TOLERANCE = 15 inside Project PCF file to increase tolerance limit for ports connection By Default it is set to value 1. Also check below wiki article for various OpenPlant Configuration variables. HTH -Regards | Rahul Kumar