Applies To Product(s): OpenPlant Modeler Version(s): 08.11.11.225 (SS6 Refresh) Environment: N/A Area: Schema Subarea: Original Author: Rahul Kumar, Bentley Product Advantage Group Overview To check new updates between OpenPlant module version 08.11.09.564 & 08.11.11.225. Below information list the files information which has been modified and newly added ones. This will aid user to check their workspace settings and confirmation. This will various files and folders mentioned for OpenPlant Modeler and OpenPlant Isometrics Manager. OpenPlant Modeler SELECT series 6 Refresh 08.11.11.225 A. Workspace Changes I. Files Modified The changes are the same for all 3 types of base projects for OpenPlant, Below are the changes shown for OPModeler Metric project Only. OPModeler_Metric.pcf Added new configuration variable OPM_2D3D_3D_CLASSES_TO_IGNORE to ignore EC Classes while generating 2D3D integration report. Bentley_Isometrics_App_Ecmodel.xml. Project path for OpenPlant : %Projects%OPModeler_Metric\DataSet\Isometrics\ The following default value has been added to the section: True WorkSpace\Projects\OPModeler_Imperial\DataSet\Isometrics\ Styles\ \Config\Report.def Project path for OpenPlant: %Projects%OPModeler_Metric\DataSet\Isometrics\Styles\IFC\Config The following sample report in report.def has been added: #------------------------------------------------------------------ # A sample weld report #------------------------------------------------------------------ REPORT = WELD include = IE_TYPE = CT_WELD COLUMN = 5:C:WELDID COLUMN = 10:R:SIZE COLUMN = 10::TYPE # the next two columns list the pipe/fitting connected by the weld. COLUMN = 30:W:left(EC_CLASS) COLUMN = 30:W:right(EC_CLASS) SORT = WELDID:N SEP = @ END Styles\ \Config\style.cfg Project path for OpenPlant : %Projects%OPModeler_Metric\DataSet\Isometrics\Styles\IFC\Config The following definition in style.cfg has become obsolete and has been removed: #-------------------------------------------------------------------- # IE_IsoNorthAngle specifies an alternative isometric north direction and is # specified as an extra counter clockwise offset in degrees from the current north #-------------------------------------------------------------------- # IE_IsoNorthAngle = 0 The following definition has been added to style.cfg as part of new functionality: #-------------------------------------------------------------------- # Additional dimensioning option for evaluation #-------------------------------------------------------------------- # to show gasket tick marks set to 1 DimTickShow = 0 # weight for gasket tick marks DimTickWeight = 3 # Cheap gasket dimensioning, Gasket are dimensioned to one side at most DimTickAll = 0 # Dimension witness line offset for centerline for a given endprep DimLift_FL = 5 DimLift_IF = 5 Styles\ \Config\style.xml %Projects%OPModeler_Metric\DataSet\Isometrics\Styles\IFC\Config The following definition in style.xml has become obsolete and has been removed: False True True 8 13 22 --> The following definition has been added to style.xml as part of new functionality: False (+%) False II. Files Added: None B. Schema Changes Changes done in latest releases: I. Schema Updates: Project path for OpenPlant : %Projects%OPModeler_Metric\DataSet\ schemas\ OpenPlant_3D_Supplemental_Isometrics_Isoextractor.01.07.ecschema.xml IE Mapping IS_SKIP is changed to false for REINFORCEMENT class The default value for the following mapping property has been changed: False Iso Extractor custom attribute applied to REINFORCEMENT class The following properties have been added: OpenPlant_3D_Supplemental_Model_Server.01.07.ecschema.xml MODELSERVER_UI_CUSTOMIZATION applied/updated on following Classes IsmCurveMember IsmSurfaceMember IsmMember OpenPlant_Supplemental_ConsistencyChecker.01.07.ecschema.xml 2D EC Property DESIGN_SIZE mapped to 3D NOMINAL_DIAMETER OpenPlant.01.07.ecschema.xml SPECID EC Property added from following EC Classes PIPING_COMPONENT INSTRUMENT PUMP NOZZLE VALVE_ACTUATOR Following EC Properties added to EQUIPMENT EC Class PLANT_NAME SYSTEM_NAME UNIT_CLASSIFICATION ADDITIONAL_CODE NUMBER_KKS New EC properties added in CONCEPTUAL_PIPE EC Class New EC Class SIZING_SIMULATION_TANK added OpenPlant_3D_Supplemental_Mapping_AutoPLANT.01.07.ecschema.xml SPECID mappings defined for AutoPLANT and OpenPlant Isometrics Manager DESCRIPTION and SHORT_DESCRIPTION mappings defined for REINFORCEMENT EC Class OpenPlant_3D_Supplemental_Modeling.01.07.ecschema.xml SPECID EC Property mappings defined for CONTROL_VALVE EC Class OpenPlant_3D.01.07.ecschema.xml DiameterUOM EC Property added for EC Class PipeAttachment SPECID EC Property removed from following EC Classes PIPING_COMPONENT NOZZLE PUMP OpenPlant Modeler SELECT series 6 08.11.11.96 (Priority Build) A. Workspace Changes I. Files Modified lisocomp.cel Style.xml II. Files Added: Hook.ini B. Schema Changes Changes done in Priority Build Releases: I. Schema Updates: Project path for OpenPlant: %Projects%OPModeler_Metric\DataSet\ schemas\ OpenPlant_3D_Supplemental_Isometrics_Isoextractor.01.07.ecschema.xml AutoPLANT BASE Relief valve Changeover (AT_VALVE_RELCHANGEOVER) OpenPlant_3D_Supplemental_Model_Server.01.07.ecschema.xml Remove right click options from smc grouping node OpenPlant.01.07.ecschema.xml Added properties SYSTEM_CLASSIFICATION, SYSTEM_NUMBER, and PREFIX to class SYSTEM. PIECE_MARK information in material list. OpenPlant_3D.01.07.ecschema.xml AutoPLANT BASE Relief Valve Changeover (AT_VALVE_RELCHANGEOVER) Change the source class of this relationship from VALVE to DEVICE to enable the handling of check valves with valve operator and other specialist valve types that are not classed under "VALVE" OpenPlant_3D_Supplemental_Mapping_AutoPLANT.01.07.ecschema.xml PIECE_MARK information in material list AutoPLANT BASE Relief Valve Changeover (AT_VALVE_RELCHANGEOVER) does not exist in OPIM schema See Also Comments or Corrections? Bentley's Product Advantage Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!
↧