Applies To Product(s): OpenPlant Project Administrator Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Managed Workspace Subarea: ProjectWise Original Author: Harpreet Singh, Bentley Product Advantage Group Problem Description Below error message appears when you log into Managed Project in OpenPlant Project Administrator. Reason This error message appears mainly due to the inability to copy out the files from ProjectWise into local drive. Since it requires a file which has CSBs attached to it from where the workspace files can be fetched and copied out locally. Steps to Resolve In ProjectWise Explorer, check if the CSBs are properly attached to the Models folder in workspace as shown below. If CSBs are not attached then attach all the required CSBs. Delete the PW local working directory and load managed workspace again. Delete managed workspace from OpenPlant Project Administrator and add again. It will not delete anything from ProjecWise, it will just delete this workspace from OpenPlant Project Administrator’s Interface. Still a Problem? If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround. See Also Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!
↧