Quantcast
Channel: OpenPlant | AutoPLANT
Viewing all articles
Browse latest Browse all 12277

Wiki Page: How to Place Pipe Nozzle Tag in Continuation on Iso

$
0
0
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX (SS4) & Above Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: Schema- Custom attribute Original Author: Berrie Geboers, Bentley Product Advantage Group Background Because the Pipe Nozzle does nor behave the same as an Equipment nozzle, it does not show the connection data and with default settings Nozzle tag will be empty as in picture below: To get pipe nozzle tag data user need to specify a new user label in OpenPlant isometric Configuration manager. See wiki articles with steps below: If user do not want to have the “ Nozzle: ” title shown in Isometrics, then " $Nozzle: $(IE_TAG):" should be removed from TEXT entry. Open "Isometric Configuration" . Select the active isometric style, pick the category “ User Labels ” and create new user label. Specify label definition as shown below: Name Pipe Nozzle Labels Include EC_CLASS=PIPE_NOZZLE Text CONN.TO.: $(EQUIPMENT_TAG) Type NOTE Cell Name NOTE Save and close the configuration manager. Create an Isometric from a pipeline that connects to a pipe nozzle to verify the result. See Also Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!