Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.87 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Processing Subarea: Component Symbol Original Author: Deepak Singh, Bentley Product Advantage Group Problem Description In isometric output, lap joint stub end shows wrong output as shown. Notice that in above image stub end is directly sitting to the flanged end of ball valve. It should have gasket sitting with flanged end of ball valve & stub should be with the flanged end of flange as shown in right hand side. Reason Wrong symbol is generating due to incorrect end prep defined for LAP_JOINT_STUB_END in spec database (*.mdb). Lap Joint will be formed for the following end preps as shown below Steps to Resolve Go to your Specs Databases folder. (as a pre-requisite user should have the basic knowledge of MS Access). C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\OPModeler_Metric\DataSet\Specs Databases. See below default path Select your spec file. Under MISC_FIT table. Go to EC_CLASS_NAME filed and search LAP_JOINT_STUB_END . Check the END_COND_1 field, ensure it should be LAP . Select any component (e.g. WELD_NECK_FLANGE ) having END_COND_1 as FL, WAF or LAP. Place a WELD_NECK_FLANGE of end condition FL, WAF and LAP here placed LAP end . Place LAP_JOINT_STUB_END with Weld Neck flange having END_COND_1 as LAP as shown below In OpenPlant Modeler Generate isometric and see the symbol for this arrangement. Still a Problem? If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround. See Also Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!
↧