Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX (SS5) | 08.11.11.224 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: Configuration Original Author: Abhijit Bute, Bentley Product Advantage Group Overview When generate isometric through Auto plant Modeler some times user face following error in AutoCAD command line. " Error: XCHG0000: Failed to initialize OpenPlant Isometric data converter 1 " Problem Description User face " Error: XCHG0000: Failed to initialize OpenPlant Isometric data converter 1 " error while generating isometrics, common reason is because of schema edited incorrectly. Below steps will help user to overcome this problem. Steps to Resolve The above errors mentioned due to wrong entries in schema, by changing project schema with out of box schema this error can be resolved. Navigate to project path. For Ex: C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_METRIC\Config\OpenPlant Rename the project schemas folder. Copy out of box schema folder of same unit, paste it on project location. For Ex: C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Configurations\Sample Metric\Config\OpenPlant Open AutoPLANT Modeler generate isometric. Still a Problem? If above problem still persist, then please create a Service Request and contact Bentley Product Advantage group along with the list of all relevant details to get in depth analysis and for possible solution or workarounds. See Also http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/20662.errors-logs-messages-crashes-openplant-isometrics-manager Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧