Wiki Page: To Resolve Error of Double Tagging Name in Pipeline

$
0
0
Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Subarea: Error Original Author: Jaya Tiwari, Bentley Product Advantage Group Overview Issue of Double Tagging Name in First Pipeline After Placing Second Pipeline. Problem Description In this Wiki Article, we will see the issue of Double Tagging Name. Sometimes, when user is placing second Pipeline in dgn the Tag Name of first Pipeline on same dgn gets changed automatically to double same Tag. Steps To Reproduce Launch OpenPlant PID. Assign Service as Sulfuric Acid. Create a Pipeline. Check the Tag Name of Pipeline through Element Information. Place a Second Pipeline on same dgn. Change some property of first pipeline lets say Number here. Verify the Tagging Name of first Pipeline, see below image. Issue: The Tagging Name of First Pipeline is changed to " U1-Sulphuric Acid-U1-Sulphuric Acid-0004-None- " Steps To Resolve Remove the space in Service Name - Sulphuric Acid to Sulphuric_Acid See Also Comments & Correction Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!