Forum Post: Dimension tolerance for very small offset in vertical pipe
In OPIM build 08.11.09.572, in our model we have a vertical pipe with a very slight offset. It's 3 inches in the horizontal for 15 feet in the vertical. It comes out to less than 1 degree. The...
View ArticleForum Post: RE: How to add bolt/gasket at equipment nozzle?
Hello Changsong, I would suggest you to log a service request for the same and upload all relevant files for further investigation. It seems there is a need to check in detail. Please share the number...
View ArticleForum Post: RE: How to add bolt/gasket at equipment nozzle?
Would you please test on the latest OPM, if move flange to a equipment nozzle, will nozzle be snapped and if bolt/gasket could be placed in this case? If it is fixed in the latest version, I may...
View ArticleForum Post: RE: Dimension tolerance for very small offset in vertical pipe
Hello Richard, Can you supply an image to it, to make it more clear to us? -Regards | Rahul Kumar
View ArticleForum Post: RE: Switching off classifications in Pointcloud
Hello Samir, Welcome to Plant forum and thanks for posting your queries. Do you want to delete few point clouds by selection in DGN file? There are two key-in's which you can try. Key-in: POINTCLOUD...
View ArticleWiki Page: How to Display Eccentric Reducer Offset Label in OpenPlant...
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.87 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: - Original Author: Rahul Kumar, Bentley...
View ArticleForum Post: RE: How to add bolt/gasket at equipment nozzle?
Yes, moving the flange back and connecting to nozzle works in the previous version as well as the latest version. Is it not working for you? Regards, Harpreet
View ArticleForum Post: RE: How to add bolt/gasket at equipment nozzle?
There is a gif attached. I placed a flange at the nozzle, the gasket/bolt was added. Then I moved the flange, deleted gasked/bolt, and then tried to move it back, you can see the nozzle cannot be...
View ArticleWiki Page: To Open Schema in Class Editor
Applies To Product(s): Bentley Class Editor Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Class Editor Subarea: Schema Opening Original Author: Deepak...
View ArticleWiki Page: How to Redeem Isoextractor Menu for Generated Isometrics
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Open/Save Subarea: - Original Author: Rahul Kumar,...
View ArticleWiki Page: How to Control Socket Weld Symbols in OpenPlant Isometrics Manager
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: Customization Original...
View ArticleForum Post: RE: Switching off classifications in Pointcloud
Hi Rahul, Thanks for your response. It's not about having multiple Point Cloud references. I have referenced 1 .pod file which is around 26 GB in size. Along with my plant components; it also has lot...
View ArticleForum Post: AutoPLANT, Insert in 3D, Not working
Hi, Using AutoPLANT SS7r1 with OPPID SS6 When using 2D to 3D, inserting equipment does nothing. How do I insert these equipment? Tag_Type = AT_EQTNK and AT_EQVES Thanks, SH
View ArticleForum Post: RE: Dimension tolerance for very small offset in vertical pipe
Here is an image. I've simplified it to make it easier to read but you can see that there is a 3 inch difference in the North location yet the drawing does not show an offset from the top of the...
View ArticleForum Post: Looking for an Object Enabler for Select Series 6 (AutoPlant &...
I'm trying to find an object enabler for displaying 2015 Bentley products on NAVISWORKS 2017.
View ArticleForum Post: RE: Looking for an Object Enabler for Select Series 6 (AutoPlant...
Hello Jose, Welcome to Plant forum & thanks for posting your query! You can download it from software fulfillment center. See below thread where similar content has been discussed. HTH -Regards |...
View ArticleForum Post: RE: Looking for an Object Enabler for Select Series 6 (AutoPlant...
Thank you! How about the ProStructures SS8 object enablers for Prosteel and Navis object enablers?
View ArticleComment on AutoPLANT V8i (SELECTseries 8) ReadMe File
This file inside the zip (AutoPLANT_ReadMe.chm) will not open correctly. other chm files from SS4-SS6 open.
View ArticleForum Post: RE: Looking for an Object Enabler for Select Series 6 (AutoPlant...
Hello Jose, As for now there are no ProStructure SS8 version for AutoCAD, Also ProStructure is not supported on AutoCAD 2017.
View ArticleForum Post: AutoPLANT V8i SS8 Create a New Project from Base Schematic Template
I have a Project that I would like to use as a Custom Base Schematic Template for creating New Projects in Project Administrator. Currently I am only presented with two options, either "Standard Base...
View Article