Forum Post: RE: Autoplant SS8 & OPIM Schema
Thanks Kestutis, I had a look but I am using Autoplant, not Openplant. the Bentley Class Editor that is installed as part of Autoplant has no such function for comparing and merging schemas. Well, not...
View ArticleForum Post: RE: Looking for an Object Enabler for Select Series 6 (AutoPlant...
Thanks Jitender to confirm. Appreciate your prompt reply on it. -Regards | Rahul Kumar
View ArticleForum Post: RE: Switching off classifications in Pointcloud
Hi Samir, As far as I understand your scenario, You want somehow to hide some portion (in your case trees) of your point cloud cata , but not entire point cloud. If yes then you can try following...
View ArticleWiki Page: Class Editor Schema Differencing and Supplementing
Applies To Product(s): Bentley Class Editor Version(s): Environment: Windows 7/8.1/10( 64 bit) Area: Class Editor Subarea: Schema Differencing Original Author: Bentley Product Advantage Group...
View ArticleForum Post: RE: Autoplant SS8 & OPIM Schema
Hi Sephen, Sorry I have pasted you other link. We have wiki about how to Differentiate schemas using Class Editor. I believe it will make your new schema customization much easier, because you will be...
View ArticleForum Post: RE: AutoPLANT V8i SS8 Create a New Project from Base Schematic...
Hello Sephen, To create a custom Base Schematic Template, simply go to the directory: C:\Program Files\Bentley\Plant V8i\Base\Options\ and either copy or create a new template. A detail information...
View ArticleForum Post: RE: Dimension tolerance for very small offset in vertical pipe
Thanks Richard, I would suggest you to create SR for this and upload Intermediate file, i models & DGN file for further investigation and enable us to discuss it further with product Management....
View ArticleWiki Page: How to Map Spec Table for Placement of Missing Component
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.11.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 64 bit Area: Component Subarea: Graphics Original Author: Harpreet Singh,...
View ArticleWiki Page: How to Use Grid Lines in OpenPlant Isometrics Manager
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.440 & Above Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: Original Author: Rahul Kumar, Bentley...
View ArticleForum Post: RE: Horizontal angle tolerance minimum for isometrics to show...
Sorry for the delay. We are using OPIM 08.11.09.572. I have tested this with SS6 also and it did not show the offset if the angle was too small. We have found the same issue with vertical pipe. I have...
View ArticleWiki Page: OpenPlant Modeler [FAQ]
Applies To Product(s): OpenPlant Modeler Version(s): V8i SELECTSeries 5, SELECTSeries 6 Environment: N/A Area: N/A Subarea: N/A Original Author: Bentley Product Advantage Group Will OpenPlant replace...
View ArticleWiki Page: How to Overwrite Revision in OpenPlant Isometrics Manager
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: Original Author: Rahul Kumar, Bentley...
View ArticleWiki Page: To Change Isometric Output Drawing Name Format
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 ( 64 bit & Others) Area: Settings/Attributes Subarea: -...
View ArticleWiki Page: How to add insulation on complete pipe after it was placed?
How to add insulation on complete pipe after it was placed? Open Project Admin. Go to Project à Piping à Update. Select in left column the field INSTHICK and if needed INSULATION (For the insulation...
View ArticleWiki Page: Error Message on Opening Existing Models in 08.11.09.564 Version
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.564 (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: File Open Subarea: Original Author: Harpreet Singh, Bentley...
View ArticleWiki Page: How to Configure OpenPlant to Allow Flange Connection with...
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Component Subarea: Properties Original Author: Harpreet Singh,...
View ArticleComment on AutoPLANT V8i (SELECTseries 8) ReadMe File
The zip file has been updated. Kindly try now.
View ArticleWiki Page: Adding “Existing” attribute to component preferences menu
Applies To Product(s): AutoPLANT Piping Version(s): N/A Environment: N/A Area: Settings/Attributes Subarea: Original Author: Artiom Jakubovic, Bentley Product Advantage Group Overview The following...
View ArticleWiki Page: How to Change the Version of AutoCAD Used on Startup. AutoPLANT...
Applies To Product(s): AutoPLANT Modeler Version(s): N/A Environment: Windows 7 32 bit, Windows 7 64 bit, Windows XP 32 bit Area: N/A Subarea: N/A Original Author: Joey Bertone, Bentley Product...
View ArticleWiki Page: To Modify Pipeline Tag Name in OpenPlant Modeler
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Properties Subarea: - Original Author: Rahul Kumar, Bentley...
View Article