Wiki Page: How to Add the Required Version to the List of Base Version for...
Applies To Product(s): OpenPlant Project Administrator Version(s): 08.11.11.87 (SS6) | 08.11.11.225 (SS6 Refresh) Environment: Windows 7/8.1/10 (64 bit) Area: OpenPlant PID Workspace Subarea: Schema...
View ArticleWiki Page: Schema Upgrade Tool
Applies To Product(s): OpenPlant Project Administrator Version(s): 08.11.11.XXX (SS6) & Higher Environment: Windows 7/8.1/10 (64 bit) Area: Schema Upgrade Subarea: - Original Author: Bentley...
View ArticleWiki Page: How to Format Data in Fractions Listed Under Drawing Tag Data
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.224 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: - Original Author: Rahul Kumar, Bentley...
View ArticleForum Post: RE: AutoPLANT PIW TO/FROM
Hello Ken - I would start with running the consistency checks under P&ID Tools. there is a urn terminator option as I recall. This will generate a log file which will show you the keytags for the 2...
View ArticleWiki Page: Configuring the BOM and Reports
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: - Original Author: Keith Couvillion, Bentley...
View ArticleWiki Page: How to avoid "Property value is not valid" warning while editing...
Applies To Product(s): Bentley Class Editor Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Class Editor Subarea: Schema Editing Original Author:...
View ArticleWiki Page: Fundamentals - Basics of Class Editor Schemas
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX(SS5) | 08.11.11.XX(SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Schema Subarea: Fundamentals Original Author: Bentley Product...
View ArticleWiki Page: What's New - SELECTseries 6
Applies To Product(s): OpenPlant Isometrics Manager Version(s): V8i SELECTSeries 6 | SS6 Refresh Environment: N/A Area: What's New Subarea: N/A Original Author: Bentley Product Advantage Group...
View ArticleWiki Page: How to Report Cut list in Multiple Columns
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: Configuring the BOM and Reports Original...
View ArticleWiki Page: How to Show Branch Diameter In Piping Reports
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 (64 bit) Area: OpenPlant Modeler Subarea: Report Definition Original Author: Deepak Singh, Bentley Product...
View ArticleForum Post: RE: Scaler, Symbols or item code are missing for Fire_Hydrant
Hello Luis, Could you please attach drawing pxf file, so that we can reproduce the issue. Looking forward to your reply. Regards, Abhijit Bute
View ArticleForum Post: RE: AutoPLANT PIW TO/FROM
Ken, Ron is correct. This is the best place to start and will help you find and resolve your incorrect To/From records. You possibly could find multiple From or To records for a singular Pipe Run. Once...
View ArticleForum Post: RE: Gaskets and Bolts on end of line valve appear on continuation...
Hello Luis, Sorry for this delay. I have just tested your provided model with our latest AutoPLANT Modeler SS8 08.11.13.211 and OpenPlant Isometrics manager 08.11.11.224 version and results where good....
View ArticleWiki Page: How to Import Piping Design Data from CSV file to Isometric...
Applies To Product(s): AutoIsogen Version(s): 08.11.09.xxx Environment: Windows XP/7(32/64 bit) Area: Processing Subarea: Original Author: Abhijit Bute, Bentley Product Advantage Group Background In...
View ArticleForum Post: RE: Gaskets and Bolts on end of line valve appear on continuation...
Thanks a lot Kestutis, We are using SS6 build. The current project is about to end, so for the next one I'll pass this info IT.. Best Regards
View ArticleForum Post: RE: Scaler, Symbols or item code are missing for Fire_Hydrant
Hi Abhijit, Thanks for your response. Attached you will find the requested file. (Please visit the site to view this file) Thanks in advance. Best Regards
View ArticleForum Post: How to create second line for information in BOM on isometric
We have a request from one of our departments to have a hard return in the information in the bill of materials so the specific information they type in will be placed on a second line in the BOM...
View ArticleWiki Page: PARTID in isometric manager shows as l/I instead of 1.
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.224 (SS6R2) Environment Windows 7/8.1/10 (64 bit) Area Settings/Attributes Subarea Isometric Configuration Original Author...
View ArticleForum Post: RE: How to create second line for information in BOM on isometric
Hi Richard, You can do this in multiple ways. In the report COLUMN definition you can concatenate multiple properties and strings using an expression. The keyword NEWLINE is interpreted as a line...
View ArticleWiki Page: To Display New Line for each Attributes in BOM
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: Original Author: Rahul Kumar, Bentley...
View Article