Forum Post: RE: How to create second line for information in BOM on isometric

Thanks Frank for this, We have also created wiki article for ready reference for the same. HTH -Regards | Rahul Kumar

View Article


Forum Post: RE: How to create second line for information in BOM on isometric

I tried this and it didn’t work for me. It either doesn’t recognize “&&&” as a new line or it is seeing it as text. I tried without the quotes and it gives me no text at all in the BOM....

View Article


Forum Post: RE: How to create second line for information in BOM on isometric

Hello Richard, Which version you testing? -Regards | Rahul Kumar

View Article

Forum Post: RE: How to create second line for information in BOM on isometric

We are using OPM build 581, OPIM build 572, and schemas 01.06 in SS5. Richard Walker | Mechanical Design Technologist Black & Veatch International | 9000 Regency Parkway, Suite 300, Cary, NC...

View Article

Forum Post: RE: How to create second line for information in BOM on isometric

Hello Richard, Can you please try with SS6 series? -Regards | Rahul Kumar

View Article


Forum Post: RE: How to create second line for information in BOM on isometric

I tried this in SS6 out of the box schemas. Starting with IM.GetValue("DESCRIPTION",IM.GetValue("NAME","NODESC")) I tried & “&&&” &, I tried just “&&&”, I tried without...

View Article

Forum Post: RE: How to create second line for information in BOM on isometric

Hi Richard, Please create Service Request and attach relevant files like an intermediate file, Report.def file to investigate the issue. -Regards | Rahul Kumar

View Article

Forum Post: RE: How to create second line for information in BOM on isometric

This may not be necessary. Kris Wishart and I looked into it yesterday. He ran the isometric and said it worked for him. I may have added an extra & in the schema. We don’t need this to work until...

View Article


Forum Post: How to Caculate the count of Insulation Materials in OPM?

Hello,everyone! I am looking for help to solve the problem 'How to Caculate the count of Insulation Materials in OPM'. After Modeling, some pipes has insulation. I want to sum the required quantity of...

View Article


Wiki Page: To round off the angular dimensions in OpenPlant Isometrics Manager

Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.224 (SS6R2) Environment Windows 7/8.1/10 (64 bit) Area Settings/ Attributes Subarea Isometric Configuration Original Author...

View Article

Forum Post: RE: How to Caculate the count of Insulation Materials in OPM?

Hello, You could create a new grid report and include in it all piping components which has insulation value greater than 0. I have tested this and got report in which where presented all piping...

View Article

Forum Post: OPM SS6 - Component dialog shows all sizes, not just the one...

Hi, I ran into a problem today. For some reason, all component placing dialog display all sizes available from spec, rather than just the one size selected in the Standard Preference dialog box. For...

View Article

Wiki: AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki

View Article


Forum Post: RE: OPM SS6 - Component dialog shows all sizes, not just the one...

HI Tuan, Could you please attach your spec to test? Regards, Harpreet

View Article

Forum Post: OPIM Dimension Config

So, I'm new to the OPIM world, so sorry if this question is off-the-charts basic in nature. What controls the way the dimensions look? I've worked thru the report.def, and got my BOM looking the way I...

View Article


Forum Post: RE: OPM SS6 - Component dialog shows all sizes, not just the one...

Does this occur in other specs?

View Article

Forum Post: RE: OPIM Dimension Config

DIM text size is controlled in the dimension style section of the seed file also a filled arrow heads. Use Save Settings to save any changes to dimension as a normal save will not keep the changes...

View Article


Forum Post: RE: OPM SS6 - Component dialog shows all sizes, not just the one...

Hi all, I think I "fixed" it. Apparently I have to leave the "Use spec default" option off, not on as shown in the OP snapshot. I'm using AT converted specs and for some reason, I have to leave all of...

View Article

Forum Post: OPM SS6 - Cross-model connectivity

Hi, Just to follow up from a previous discussion about cross model connectivity, it happened mid-post from this thread: Just a summary, I've got line A in A.dgn and line B in B.dgn. In B.dgn, line A is...

View Article

Forum Post: OPIM SS6 - OPMdir.cfg file location

Hi, It seems the location for OPMdir.cfg file is fixed to "C:\Program Files (x86)\Bentley\OpenPlantIsometricsManager V8i\OpenPlantIsometricsManager\config" Is there any chance I can relocate that file...

View Article
Browsing all 12277 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>