Forum Post: RE: How to Caculate the count of Insulation Materials in OPM?
Dear Mr Mitkus: Hello, Thanks very much for your answer. I've tried this way you provided, and I could report like this. Now, I've some another problems that I want report this as crystal report not...
View ArticleForum Post: OPM SS6 - Remove PLANT_AREA from Instrument name
Hi, I'm trying to remove PLANT_AREA from Instruments' names as we don't use PLANT_AREA, and not plan to. I've made the changes in the INSTRUMENT class, based on which the class PRESSURE_GAUGE is...
View ArticleWiki Page: To Remove Plant Area Property from Tag of Gauge Class
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Component Subarea: Original Author: Harpreet Singh, Bentley...
View ArticleForum Post: RE: OPM SS6 - Remove PLANT_AREA from Instrument name
Hi Tuan, Please refer below wiki article to remove area from tag. Hope this helps! Regards, Harpreet
View ArticleForum Post: RE: OPM SS6 - Cross-model connectivity
Hi Tuan, You are seeing connectivity information in file B, because the joint is created in B.dgn. So, if you publish I-model from file B and run the iso, you will get the continuation in iso. Regards,...
View ArticleForum Post: RE: OPM SS6 - Remove PLANT_AREA from Instrument name
Hi Harpreeet, Thanks very much for the link to wiki, works as expected. Tuan
View ArticleForum Post: RE: OPM SS6 - Cross-model connectivity
I get that Harpreet. There's no issue with line B's iso metric. However, there's no continuation information on line A's iso, and that's what I'm trying get. If everything works well, both lines A...
View ArticleForum Post: RE: OPM SS6 - Cross-model connectivity
Oops, I think I understand what you mean now. Using the i model of line B to extract isometric for line A as well, rather than extract line A's isometric from its own i model. That does seem to work....
View ArticleForum Post: RE: OPIM SS6 - OPMdir.cfg file location
Hi Tuan, Could you please tell us why do you want to move OPMdir.cfg file to network location? Regards, Harpreet
View ArticleWiki Page: How To Display Pipe Length using Multipliers
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.404 & above Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: - Original Author: Rahul Kumar,...
View ArticleForum Post: RE: OPIM SS6 - OPMdir.cfg file location
Because we are using networked workspace, so the file has to be modified for that. Being locally to each PC, if there's a software update/reinstall, that file will have to be re-modified for each PC,...
View ArticleForum Post: OPIM SS6 - Gauge label missing
Hi, For some reason the label for gauges only show device type code part and missing the number part, as shown in the snapshot below: I've checked the setting for IFC labels and couldn't see any issue:...
View ArticleForum Post: RE: OPIM SS6 - Gauge label missing
Hi Tuan, You need to remove "-I" from Flags field in labels. Once removed, save the changes and verify the result. You will see full name in iso drawing. You can find more information about use of...
View ArticleForum Post: RE: OPIM SS6 - Gauge label missing
Hello Tuan, In addition to this, you could also check below wiki article for referring the Tags inside the cell. HTH -Regards | Rahul Kumar
View ArticleForum Post: RE: Scaler, Symbols or item code are missing for Fire_Hydrant
Fire hydrants were not supported in the 1.04 schemas ; newer schema versions have support for fire hydrants. The mappings can be added to the 1.04 schemas and may work or the schemas and cells be...
View ArticleForum Post: RE: OPIM SS6 - Gauge label missing
Thanks Rahul, it works. Best regards, Tuan
View ArticleWiki Page: How to Make Pressure Reducing Valve Orient to Bigger Size
Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Configuration Subarea: Original Author: Harpreet Singh, Bentley...
View ArticleWiki Page: Modifying Dimensions
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.5xx Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: - Original Author: Keith Couvillion, Bentley Product...
View ArticleForum Post: RE: OPIM SS6 - OPMdir.cfg file location
Hi Tuan, Thanks for the confirmation. You can place OPMdir.cfg file on network location and update mslocal.cfg file in the same config folder as shown below. As mentioned above in picture, I created a...
View ArticleWiki Page: PARTID in isometric manager shows as l/I instead of 1.
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.224 (SS6R2) Environment Windows 7/8.1/10 (64 bit) Area Settings/Attributes Subarea Isometric Configuration Original Author...
View Article