Comment on OPPID - Minor piperun as part of Primary Pipeline
Yes this should also work for Equipment.
View ArticleForum Post: OPIM for AutoPLANT SS5 Isometric Splitting
Hi, Currently working with AutoPLANT SS7 and Open Plant Isometric Manager in AutoPLANT access mode SS5. How can I alter the automatic isometric splitting settings or do I have to move to SS6? Currently...
View ArticleForum Post: RE: OPIM for AutoPLANT SS5 Isometric Splitting
Hello Kyle, Thanks for posting your query to PLANT forum! Could you please let us know which wiki article you referred regarding iso splitting? -Regards | Rahul Kumar
View ArticleForum Post: RE: OPIM for AutoPLANT SS5 Isometric Splitting
Hi Rahul, communities.bentley.com/.../29903.how-to-use-various-iso-sheet-splitting-options-in-openplant-isometrics-manager I know this is for SS6. I did have a minor win this morning in getting OPIM to...
View ArticleForum Post: RE: OPIM for AutoPLANT SS5 Isometric Splitting
Hello Kyle, Iso splitting option available with OpenPLANT Isometrics Manager SS6 Version, you need to upgrade to OpenPlant Isometrics version SS6. I would like to suggest that install latest OpenPlant...
View ArticleForum Post: How to get a dash between Feet and Inches in OPIM dimensions
OPIM V8i SS6 (v08.11.11.224) AutoPLANT Modeler V8i SS8 (v08.11.13.211) Need a dash to be inserted in my dimesions so that they read 1'-10 3/8" In the Dimension style, I have tried to set it to MU labe...
View ArticleForum Post: RE: How to get a dash between Feet and Inches in OPIM dimensions
Hello Jesse, You can also give try using Style.cfg file. There are many options present. Please have a look below. HTH -Regards | Rahul Kumar
View ArticleForum Post: RE: OPIM SS6 - Field Fit Allowances per pipe length, not per weld...
Tuan, This is currently not possible. Maybe you can elaborate a bit more on why 2 FFW's are used on the same pipe run. The FFW is normally only specified on one end of the pipe run, the other end would...
View ArticleForum Post: ECExpression String Escape sequence
Example: this.NOMINAL_DIAMETER & """-" & this.LINENUMBER & "-" & this.SPECIFICATION &"-" & this.INS_CODE & "-" & System.String.Format("{0:D2}", this.INS_THK*1) Would in...
View ArticleForum Post: In OPPID: how can I obtain the specified level which...
For example,In OPPID,when I drawing pipeline, using by Major Pipeline tool, item of sevice :EG, see 1.png. as I see the information of the pipeline, in level displayed :Major Process,see 2.png.In...
View ArticleForum Post: RE: In OPPID: how can I obtain the specified level which...
Hi Wang, I believe below wiki article will help you in this case. Hope this helps! Regards, Harpreet
View ArticleForum Post: RE: In OPPID: how can I obtain the specified level which...
hi ,i have viewed this article. it is different. i once test by this article. it can not get my need ansewer!
View ArticleForum Post: RE: In OPPID: how can I obtain the specified level which...
i focus on level not color.
View ArticleWiki Page: How to Assign Color by Service to the Pipeline
Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Customization Subarea: Original Author: Harpreet Singh, Bentley...
View ArticleForum Post: RE: In OPPID: how can I obtain the specified level which...
Hi Wang, I have made some changes in the steps, this will give you the color as well as level both. Please give it a try. Regards, Harpreet
View ArticleForum Post: RE: AutoPLANT Error! It won't start. 'unable to read the AT.INI file
Hey I have do this but now i have tjis message : AutoPLANT Loaded ...; Error: incorrect argument type: stringp nil Can you help me ?
View ArticleForum Post: RE: In OPPID: how can I obtain the specified level which...
may be it is possible. but i hope when i chose major pipeline, the weight of the pipeline is the same as the major pipeline, not the weight by level defined, others are the same as the level which...
View ArticleForum Post: RE: In OPPID: how can I obtain the specified level which...
Yes, it is possible. You will need to set the same weight to the template which is 2 for Major Pipeline. Regards, Harpreet
View ArticleForum Post: RE: In OPPID: how can I obtain the specified level which...
addition, why is the service not service_name? what is the different?
View ArticleWiki Page: Open Plant PID Grid and lock settings
Open Plant P&ID Grid and lock settings Placement snap is dictated by Lock Settings Values from this drawing settings dialog are saved in user config file, not the projects pcf file, making this a...
View Article