Forum Post: RE: In OPPID: how can I obtain the specified level which...
I have test just now.in my resulet display, the level is my needed. But the weight is not my need. i want get the weight of major pipeline, not the weight set by level which service in .how to do it?
View ArticleForum Post: RE: OpenPlant PID create pick list on EC Property using External...
Hello Harpreet, Has there been any progress with my question? This is getting more urgent that I find a solution. I've created ticket 7000616720 to do the follow up. Thanks Alain
View ArticleForum Post: Autoplant Reinforcing Pad not shown in bill of materials of...
Good ay, Reinforcing pads are not listed in the bill of materials of the isometric. Please notice that the reinforcing pad symbol is shown (as seen below) Versions in use: Autoplant version:...
View ArticleForum Post: RE: ECExpression String Escape sequence
Hello Peter, Have you checked posted links on this wiki? I have searched for some possible information and found this article: Test posted suggestions and update us about your results. Regards,...
View ArticleForum Post: RE: ECExpression String Escape sequence
Hello Peter, Are you trying it for some output or is there a general concern of using expressions? -Regards | Rahul Kumar
View ArticleForum Post: RE: OPM User defined Valves Insulation
Hello Peter, For custom components, graphical update is not supported. However you may feed the information in property regarding insulation to to be extracted as reports. Alternatively, you can also...
View ArticleForum Post: RE: ECExpression String Escape sequence
Kestutis, Rahul Yes, have looked at standard escape sequencing. The page U linked Kestutis is a good guide, thx. However: What I started trying was two things. 1) Enter " into a string. In this case a...
View ArticleWiki Page: To keep the piece marks well placed inside the note box in...
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area Settings/Attributes Subarea: Isometric Configuration...
View ArticleForum Post: RE: OpenPlant PID create pick list on EC Property using External...
Hi Alain, I have been able to simulate the problem on my side and currently looking for a solution. We will correspond through SR channel from now onwards. Regards, Harpreet
View ArticleWiki Page: To Move Drawing Tag in Output Drawing
Applies To Product(s): OpenPlant Orthographic Manager Version(s): 08.11.09.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64-bit) Area: Drawing Editor Subarea: Drawing Tag Original...
View ArticleForum Post: There is a question for OpenPlant Specification Generator.
There is a question for OpenPlant Specification Generator. Is there user input & Keyin fields ? I can’t find it. I want to need a various display and description of material and manufacture as per...
View ArticleWiki Page: Modifying Dimensions
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.5xx Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: - Original Author: Keith Couvillion, Bentley Product...
View ArticleWiki Page: How to update spec data in existing valves in OpenPlant PID
Applies To Product(s): OpenPlant PID Version(s): 08.11.11.XXX (SS6R) Environment: Windows 7/8.1/10 (64 bit) Area: Manipulation Subarea: Original Author: Jaya Tiwari, Bentley Product Advantage Group...
View ArticleForum Post: RE: OPM: Write the number of Elements on a Level into a Text File...
Hello Rahul Excuse my delayed response to your post and thanks for the quick reply to my question. I've been trying in the meantime to solve the problem. I found a solution, but unfortunately, this...
View ArticleWiki Page: Adding Custom Fields into Component Indexing
Applies To Product(s): ProjectWise, AutoPLANT Piping Version(s): 08.11.07.XX Environment: N/A Area: N/A Subarea: N/A Original Author: Richard DeLong, Bentley Technical Support Group Overview This...
View ArticleWiki Page: How to Suppress ‘UBR_STUB_IN’ in OpenPlant Isometrics Manager Bill...
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: - Original Author: Abhijit Bute, Bentley Product Advantage...
View ArticleForum Post: RE: Autoplant Reinforcing Pad not shown in bill of materials of...
Hello Luis, Using this wiki article check which EC_CLASS or IE_TYPE values has this component. Then using this wiki article include component's EC_CLASS or IE_TYPE in your report.def file and test your...
View ArticleForum Post: RE: There is a question for OpenPlant Specification Generator.
Hello Park, If I understood you correctly, you would like to rebuild, edit or change component descriptions in your Specification? This wiki article should assist you in this task: If I misunderstood...
View ArticleForum Post: Populating Titleblock Information in Isosheet Manager
Product: OpenPlant Modeler V8i (SS5) 08.11.09.440 I'm looking for a way to quickly populate titlebock information and revision history with in Isosheet Manager. My thoughts were that this would be very...
View Article