Forum Post: Change 'Modify Component' or 'Element Info' Default Settings

How can I change the Modify Component Dialog to have certain Sections open by default? And how can I move properties between the sections?

View Article


Forum Post: RE: Change 'Modify Component' or 'Element Info' Default Settings

Hi Shaun, Please refer below wiki article for moving properties to different section. For expanding the category by default, you must set Expand field to 'True' in CATEGORY custom attribute as shown...

View Article


Wiki Page: How do I change the slant of text for Piping Annotation in...

Applies To Product(s): AutoPLANT P&ID Version(s): V8i Environment: N\A Area: N\A Subarea: N\A Original Author: Brandon Moberg, Bentley Product Advantage Group 1. Open the Pid-Sup.lsp File. 2....

View Article

Forum Post: RE: OPM SS6 - Connecting components of different rating

Hi Tuan, Thanks for the SR, this issue is logged as an Enhancement # 683247 . Regards, Harpreet

View Article

Forum Post: Replaced Bolts using Fix Disconnects

Hello, I have deleted bolts (approx. 150 sets) due to a bolt length error in the specification. I replaced then by using the "Fix Disconnects" command and now they do not show up on the isometrics....

View Article


Forum Post: Moving an object (tank) in OPM after it has been worked on in...

I have several tanks modeled in OPM SS6, but because OPM doesn't give the option for angle iron legs (OPM only does round or square legs) I have our structural designer add the legs in AECOSim SS6....

View Article

Forum Post: RE: OPM SS6 - Cannot change pipeline with multiple tapping...

Hi Rahul, Just wondering if there's an update on this? Best regards, Tuan

View Article

Forum Post: RE: OPM SS6 - Connecting components of different rating

Thanks Harpreet.

View Article


Forum Post: RE: Replaced Bolts using Fix Disconnects

Hi, 1. You can check first by creating iso sheet again and verifying it inside iso sheet manager if sheets created successfully. 2. In intermediate file, check if fasteners available or not. Are there...

View Article


Forum Post: RE: Moving an object (tank) in OPM after it has been worked on in...

Hello Gary, I am not sure if this supports or some way to unlock AECOsim component. There are structural Members present in OpenPlant Modeler, which you may choose to select for desired section type....

View Article

Forum Post: RE: OPM SS6 - Cannot change pipeline with multiple tapping...

Hello Tuan Le, I have reproduced the case using default mEX-OPM & mA1-OPM. This is a known issue. Please create an SR so that we could update the same. HTH -Regards | Rahul Kumar

View Article

Forum Post: RE: Moving an object (tank) in OPM after it has been worked on in...

Thanks Rahul, I would like to see Bentley add another option for angle legs in the vertical vessel. The only options now are round and square. We also need to be able to add baseplates to the legs....

View Article

Forum Post: Bentley Navigator, PDMS rvm file read

Hi, Autodesk NavisWorks can read PDMS Aveva rvm file format. Could Bentley Navigator do the same? Many of our third party are using Aveva PDMS and we need to do the model review with both AutoPLANT and...

View Article


Forum Post: RE: Replaced Bolts using Fix Disconnects

Hi Rahul, 1. Waiting on my designer to verify however this would not be a good solution as there are many iso sheets that would have to be re-done. 2. The intermediate file does not include bolts....

View Article

Forum Post: RE: Bentley Navigator, PDMS rvm file read

Hello Stephane, Bentley Navigator connect edition enlist the support for reading rvm, VUE, DWG, etc file format. Any non i-model would first needed to convert to DGNdb based i model and then further...

View Article


Forum Post: RE: Moving an object (tank) in OPM after it has been worked on in...

Thanks Gary, I will dig out further & update you on this. Meanwhile request you to create one SR for logging it for OpenPlant Modeler. HTH -Regards | Rahul Kumar

View Article

Forum Post: RE: OPM SS6 - Cannot change pipeline with multiple tapping...

Hi Rahul, SR 7000624034 is raised. Best regards, Tuan

View Article


Forum Post: OPM SS6 - Default value for custom property of...

Hi, What would be the proper way to define a default value for a custom property of PIPING_NETWORK_SYSTEM class. I came across this thread: But that seems to work with properties defined in...

View Article

Forum Post: RE: OPM SS6 - Threaded tap port

Hi Rahul, Sorry for the late reply. I didn't see your reply in the SR channel so didn't get back to it. And now the SR has been closed so I couldn't reply to it. With what you proposed in the SR, I...

View Article

Forum Post: RE: OPM SS6 - Default value for custom property of...

Hello Tuan Le, Yes you are right! You need to open OpenPlant.01.07 schema and supplemental it with OpenPlant_Supplemental_Tagging schema. See below wiki article for similar issue. HTH -Regards | Rahul...

View Article