Forum Post: RE: OPM SS6 - Default value for custom property of...
Hi Rahul, Thanks for that. But what I want to do is to assign a default value to a property of PIPING_NETWORK_SYSTEM, such as OPERATING_TEMPERATURE. So whenever a new pipe line is defined, that field...
View ArticleForum Post: RE: OPM SS6 - Default value for custom property of...
Hello Tuan Le, There are two ways you can define it. On Project level control , you need to use OpenPlant.3D.01.07 schema and define it under Pipeline (PIPING_NETWORK_SYSTEM) class by adding custom...
View ArticleForum Post: RE: OPM SS6 - Threaded tap port
Do you need an empty tap placed on a pipe and have it noted on the iso as a threaded open port or will a component be placed on the tap?
View ArticleForum Post: RE: OPM SS6 - Threaded tap port
Hi Joey, A component will be placed in the tap. Best regards, Tuan
View ArticleForum Post: RE: Change icon in menu task OPPID
Hi Nuno, The wiki link is about how to create icon. And also you can get it from Help file. Help > Content Regards, Jaya
View ArticleForum Post: COMOS and OPENPLANT
Do any one know informations anout the Integration from COMOS to openplant ? and how do you save the file Export from comos PID to the imodel and then to OPENPLANT?
View ArticleWiki Page: How to Delete-Modify Sections in Specification Generator
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: OpenPlant Specification Generator Subarea: - Original Author:...
View ArticleForum Post: RE: COMOS and OPENPLANT
Hello Mona, Thanks for your query on Plant forum! Yes, there are discussion going on about integration of COMOS with OpenPlant. However on its working we will update you shortly on this. -Regards |...
View ArticleForum Post: RE: OPM SS6 - Threaded tap port
Hello Tuan Le, You can request to open your closed SR at any point of time and you feel if there is still need of discussion. I will open it again for you. -Regards | Rahul Kumar
View ArticleForum Post: RE: COMOS and OPENPLANT
Thank you for your reply. However I need information about how to get an idgn file from COMOS, if you can help me in this.
View ArticleWiki Page: OpenPlant Support Engineering [FAQ]
Applies To Product(s): OpenPlant Support Engineering Version(s): V8i Environment: N/A Area: N/A Subarea: N/A Original Author: Bentley Product Advantage Group What are the prerequisites required to...
View ArticleWiki Page: Error [20218]: Cannot Start Application For the Specified Document
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: ProjectWise Subarea: Original Author: Harpreet Singh, Bentley...
View ArticleWiki Page: "[Error 319] Cannot Start Application for the Specified Document"...
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: ProjectWise Subarea: Original Author: Harpreet Singh, Bentley...
View ArticleForum Post: RE: COMOS and OPENPLANT
Hello Hegazi/Rahul, Please coordinate with Gert-Jan Straatsma Gert-Jan.Straatsma@bentley.com - he has experience working on this workflow. Regards, Mehreen
View ArticleForum Post: RE: Replaced Bolts using Fix Disconnects
Hi Rahul, Were you able to reproduce the same problems that we are experiencing?
View ArticleForum Post: RE: OPM SS6 - Threaded tap port
Looks like this is a defect. The tapport can be one of several different connections depending on the end type of the connecting component. OPM does not place weld symbols for threaded components and...
View ArticleForum Post: RE: COMOS and OPENPLANT
Thanks Mehreen, We have sent the information to our experts here. Mona, you will be getting some update shortly on this. Thanking you for your patience in this regard. -Regards | Rahul Kumar
View ArticleWiki Page: Message Please install OpenPLANT PID or Bentley I&W or AutoPLANT...
Applies To Product(s): Bentley DataManager Version(s): V8i Environment: N\A Area: N\A Subarea: N\A Original Author: Brandon Moberg, Bentley Product Advantage Group Error - No License found - when...
View ArticleWiki Page: To Create Elbow Fitting with Clamp Length in OpenPlant Modeler
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.87 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Component Subarea: Elbow Original Author: Rahul Kumar, Bentley Product Advantage...
View Article