Quantcast
Channel: OpenPlant | AutoPLANT
Browsing all 12277 articles
Browse latest View live
↧

Forum Post: RE: Projectwise and Bentley AutoPLANt P & ID

Also is there an interface between Bentley AutoPLANT P & ID/OpenPLANT and REVIT - or an interface from Bentley AutoPLANT P & ID to 3D Bentley AutoPLANT to REVIT..we need to be able to access...

View Article


Forum Post: RE: Projectwise and Bentley AutoPLANt P & ID

Hello Paul, ProjectWise is the project team collaboration and work sharing platform. This integrates with AutoPLANT and OpenPlant and has a plug-in for Revit integration. AutoPLANT and OpenPlant PID...

View Article


Forum Post: RE: OPModeler Changing the unit of displayed diameters

Hi Harpreet, That works great, thanks. The issue I'm still experiencing though is that now both the Nominal Diameter and Display Size properties are displayed in the standard preferences interface. My...

View Article

Forum Post: RE: OPModeler Changing the unit of displayed diameters

This custom attribute will not work in this case until 'Standard Preference' Custom Attribute is there on NOMINAL_DIAMETER property. If you remove that custom attribute then it will not filter the...

View Article

Forum Post: RE: Projectwise and Bentley AutoPLANt P & ID

Thanks Tony for your assistance....much appreciated

View Article


Forum Post: RE: OPIM error: Scaler, Symbols, or item code are missing for...

Hello Karl, I would like to suggest please run connectivity checker and correct all disconnects before generating isometric. Hope this helps. Looking forward to your reply. Regards, Abhijit Bute

View Article

Forum Post: RE: Wrench Operator Swing Direction - AutoPLANT & OPIM

Hello Sean, This can not be configured now. However we would like to request you to log a Service Request with relevant details to allow it to file as an Enhancement. -Regards | Rahul Kumar

View Article

Forum Post: OPPID command line?

Is there some sort of utility provided as part of OPPID where we could synchronize file data with the SQL server database, without having to have the file open in OPPID? Right now, for certain office,...

View Article


Comment on How to Setup a Batch Routine to Sync all Drawings in my Project to...

This prompts with a 'sync complete' each time a file successfully syncs. Is there a way to NOT have that happen? Also, is there a way for it to note errors/failures, and move on to the next file? It...

View Article


Forum Post: RE: AutoPLANT Piping Reports for Bulk MTO not showing bolt...

Finally got it working, thanks for the advice. Had to add the Long Description in Project Administrator to the available fields under Reports, also BOLT_DIA & BOLT_LEN. Update components in the...

View Article

Forum Post: RE: OPPID command line?

Hi Kirk, I guess you have already referred to below wiki for batch sync. Regarding your question on the same article whether dialogs on successful sync can be suppressed? No, at the moment these...

View Article

Comment on How to Setup a Batch Routine to Sync all Drawings in my Project to...

Hi Kirk, This is not possible with current release of OpenPlant PID. However, next release will have this feature. Regards, Harpreet

View Article

Wiki Page: To Obtain Bend Angle For Pipe Bends/Mitered Bends in reports,...

Applies To Product(s): OpenPlant Reporting Version(s): 08.11.09.564 Environment: Windows 7 (64 bit) Area: - Subarea: - Original Author: Rahul Kumar, Bentley Product Advantage Group Overview To include...

View Article


Wiki Page: Gaskets Not Converted from PSDS Spec to OpenPlant Modeler Spec

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.xxx Environment: Windows 7 (64 bit) Area: Component Subarea: - Original Author: Harpreet Singh, Bentley Product Advantage Group Problem...

View Article

Wiki Page: How to create custom Valve End Conditions using existing graphics

Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX Environment: Windows 7 (64 bit) Area: Customization Subarea: Original Author: Harpreet Singh, Bentley Product Advantage Group To add custom...

View Article


Forum Post: How i can give Directional Support Guides attributinformation out...

Dear all, i wanna give the Directional Support Guides the Attributinformation out of my pipeclass. At the moment i get any random Attributinformation out of the system. i had try to add the custom...

View Article

Forum Post: RE: How i can give Directional Support Guides attributinformation...

Hi Markus, Could you please explain with some snapshots? Regards, Harpreet

View Article


Comment on Repairing Missing Component Data In AutoPLANT 3D 2004 Edition [CS]

hello, i had the same problem as this, although the fix above didn't work for me. i raised a service request and the answer turned out to be pretty simple. open your project in Relationship Manager,...

View Article

Forum Post: RE: How i can give Directional Support Guides attributinformation...

Hello Markus, Thanks for posting you query on communities. If you are using OpenPlant Modeler Version 08.11.09.440 & similar 4XX series version, then you will not achieve this as there were some...

View Article

Forum Post: RE: How i can give Directional Support Guides attributinformation...

Nice thats helps me, i use atm the xx.440 version but then i will try it later on .564 after a schema update. I post my result hear later.