Quantcast
Channel: OpenPlant | AutoPLANT
Browsing all 12277 articles
Browse latest View live

Forum Post: RE: Release Announcement – Update 2 for AutoPLANT V8i...

You are absolutely right Igor. The list has been corrected with duplicates removed. Thanks.

View Article


Forum Post: RE: Release Announcement – Update 2 for AutoPLANT V8i...

Hi Adnan! Was glad to help! Best Regards, Igor Martynets e-mail: martynets@rusapr.ru www.bsapr.ru

View Article


Forum Post: ISO Drawing(OpenPlant Isometrics Manager...

ISO Drawing:The comma is always the first in the next line,I hope the comma is at the end of the first line. 1 2 3 4 5 6 7 8 a Too long to be aligned 9 I hope alidn 10

View Article

Wiki Page: In Isometric Extraction Eccentric Reducer Flat Side note should...

Applies To Product(s): AutoPLANT Isometrics Version(s): (SS4)08.11.09.140 Environment: Windows 7 Area: Settings/Attributes Subarea: Original Author: Vidit Ruhela, Product Advantage Group Overview how...

View Article

Wiki Page: How to Manage Component Symbology for Cable Tray Components

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.11.XXX (SS6) Environment: Windows 7\8.1\10 (64 bit) Area: Settings/Attributes Subarea: - Original Author: Kunal Kiran, Bentley Product...

View Article


Forum Post: RE: Error Message : “FATAL ERROR : Unahandled e0434352h Exception...

Hello Kestutis, We tried both proposals and unfortunately the problem continues. Avi C.

View Article

Forum Post: RE: ISO Drawing(OpenPlant Isometrics Manager...

Hello Chen Xin, I would suggest you to create an SR for this item to get in depth analysis by experts and could be able to contact you in case it require some live meeting for demonstration. Further...

View Article

Wiki Page: How to Set Same Level to Major & Minor Pipeline but Different Line...

Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Class Editor Subarea: Customization Original Author: Jaya Tiwari,...

View Article


Wiki Page: To set predefined levels for piping components based on the...

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: - Original Author: Kunal Kiran, Bentley Product...

View Article


Wiki Page: To put Catalogs and Specs in a different folder out of default...

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: - Original Author: Kunal Kiran, Bentley Product...

View Article

Wiki Page: Bentley AutoPLANT and Navisworks

Applies To Navisworks users who need to view AutoPLANT graphics Product(s): AutoPLANT Piping / Equipment / Modeler Version(s): 08.11.10.182 Environment: Windows 7 32 bit, Windows 7 64 bit, Windows XP...

View Article

Wiki Page: AutoPLANT Issues with Navisworks

Applies To AutoPLANT Product(s): AutoPLANT Piping Version(s): 08.11.09.140 Environment: N/A Area: General Subarea: Original Author: Joey Bertone, Bentley Technical Support Group Background Autodesk...

View Article

Wiki Page: Using The AutoCAD 2005 Compatibility Tool [CS]

This Client Server article is republished in its entirety from 2005 for reference purposes. By Bentley Technical Support Group 22 April 2005 Modified: 28 April 2005 The AutoCAD 2005 Compatibility tool...

View Article


Wiki Page: How to update spec data in existing valves in OpenPlant PID

Applies To Product(s): OpenPlant PID Version(s): 08.11.11.XXX (SS6R) Environment: Windows 7/8.1/10 (64 bit) Area: Manipulation Subarea: Original Author: Jaya Tiwari, Bentley Product Advantage Group...

View Article

Forum Post: Error While generating Piping BOM,Gasket BOM

Dear All, Am facing error while generating Piping BOM,Bolt BOM & Gasket BOM report . the type of error is as described below, I nvalid Query The Property 'Line_No' is not in the selected class or...

View Article


Forum Post: RE: Autoplant and autocad

Hi Yes, AutoPLANT Modeler V8i SS7 version 08.11.12.235 does support AutoCAD 2015. You can download read-me files from below link for more details about system requirements. You need to make sure that...

View Article

Forum Post: RE: Autoplant and autocad

may I add, Autocad Architecture 2015 or AutoCAD mechanical or Design Suite will also work in most cases, its just that, not all possible combinations are tested and hence not mentioned. Therefore some...

View Article


Forum Post: RE: Error While generating Piping BOM,Gasket BOM

Hi Vishal, Are you generating report from OpenPlant Modeler with default template or you made some changes in query & getting issue now? You can use default template to run query and let us know if...

View Article

Forum Post: RE: Autoplant and autocad

I have read the system requirements for autoplant ss7 and there they did not mention about autocad architecture. Only Autocad 2015 version is mentioned.

View Article

Forum Post: RE: query for Bentley Software

Hello Aayush Baranwal, I will forward your question to my colleagues who will be able to recommend you relevant Bentley product. Best Regards, Kestutis M.

View Article
Browsing all 12277 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>