Wiki Page: How to Cascade Properties from Pipeline to Associated Supports
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) Environment: Windows 7/8.1/10 (64 bit) Area: Component Subarea: Original Author: Harpreet Singh, Bentley Product Advantage Group...
View ArticleForum Post: RE: moving components coordinately in AutoPLANT 3D 2012 version.
Hello Rachel, Thanks for your question. For example, I want to copy/move a circle from current location (let’s say absolute coordinates 1000,1000,1000) To a point located at a delta coordinates DX1000,...
View ArticleWiki Page: To Query the Mating Components Based on Auto-Match
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) Environment: Windows 7/8.1/10 (64 bit) Area: Component Subarea: Original Author: Harpreet Singh, Bentley Product Advantage Group...
View ArticleForum Post: RE: Continuation Missing On Isometrics (OpenPlant)
Hello Sean, Could you please mention AutoPLANT version and OpenPlant Isometrics Manager version. I have tried to reproduce your issue on my side it seems I am getting continuation line information....
View ArticleForum Post: RE: Continuation Missing On Isometrics (OpenPlant)
Hi Abhijit, Using: Autoplant Modeller V8i Select Series 6 OpenPlant Isometrics Manager V8i Could it be anything in the overrides.txt file I may have set in error? Kind Regards, Sean
View ArticleForum Post: RE: Continuation Missing On Isometrics (OpenPlant)
Hello Sean, Their is no any setting to in override txt to control continuation. I am suspecting you might working on older version of AutoPLANT modeler 08.11.11.113. Could you please send me following...
View ArticleForum Post: Shop and Field Weld Report in Isometric Manager
Is there a property to Exclude in the Report definition so we can run a Weld Id list separated into Shop and Field Welds? Right now my Report look like this:...
View ArticleForum Post: RE: Shop and Field Weld Report in Isometric Manager
Hi Brynn, The best thing here would be to use a slightly different approach, include the welds and exclude the field items, like: INCLUDE = IE_TYPE=CT_WELD EXCLUDE = IE_FIELD=1 Regards, Frank
View ArticleWiki Page: Weld Tags Sorting in Numerical and Sequencing Order in OpenPlant...
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX (SS5) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: Original Author: Rahul Kumar, Bentley...
View ArticleForum Post: RE: Shop and Field Weld Report in Isometric Manager
Thanks Frank, Brynn, you could also check similar wiki for your reference HTH -Regards | Rahul Kumar
View ArticleComment on AutoPLANT Plant Design (Imperial): Final Plant virtual class for...
kindly send me auto plant notes on my Gmail account. thanks
View ArticleForum Post: RE: Error[5]Cell not found in Libraries: CRE
The end preps for this component (concentric reducer) are probably not mapped in the supplemental isometrics schema. Endprep mapping is done in the PLANT_BASE_OBJECT/WELD_VALUE_MAP class, the...
View ArticleForum Post: OpenPlantPID/Class Editor
If I'm looking in the OpenPlant_PID.01.07 schema, under devices>Any item that has a Schematic CAD custom attributes, see picture on left Where is the Cell library location mapped? I realize that...
View ArticleForum Post: RE: Instrument location codes in OPPID
Hello Gary, Currently, automatically extracting the grid data from OpenPlant PID is not possible. As far as using the fields LOC_CODE or INSTR_LOC - you could use either field. In my initial post I...
View ArticleForum Post: RE: OpenPlantPID/Class Editor
Hello Cole, Inside OpenPlant PID (Workspace>Configuration) you can find two variables, which are responsible for cell library directory mapping: MS_CELL MS_CELLLIST I hope this information will be...
View ArticleFile: Readme file for OpenPlant Orthogrpahics Manager V8i SELECTseries 6 Refresh
Readme for OpenPlant Orthographics Manager V8i SELECTseries 6 Refresh 2 release (version 08.11.11.305) is available now. Kindly review it for release notes, installation requirements, pre requisites...
View ArticleFile: Readme file for OpenPlant Modeler V8i SELECTseries 6 Refresh 3
Readme for OpenPlant Modeler V8i SELECTseries 6 Refresh 3 release (version 08.11.11.304) is available now. Kindly review it for release notes, installation requirements, pre requisites and what's new...
View ArticleFile: Readme file for OpenPlant ModelServer V8i SELECTseries 6 Refresh
Readme for OpenPlant ModelServer V8i SELECTseries 6 Refresh release (version 08.11.12.229) is available now. Kindly review it for release notes, installation requirements, pre requisites and what's new...
View ArticleFile: Readme file for OpenPlant ModelServer Administrator V8i SELECTseries 6...
Readme for OpenPlant ModelServer Administrator V8i SELECTseries 6 Refresh release (version 08.11.12.229) is available now. Kindly review it for release notes, installation requirements, pre requisites...
View Article