Forum Post: Can you disable synchronization of a class of P&ID components?
Is there a method to disable the synching of a class of components such that the sync mapping does not default to that of a higher class? For example, the INSTRUMENT class is mapped and synched to the...
View ArticleForum Post: Open plant Isometric manager error
We are able to connect to test environment with OPIM but when we connect to production datasource and click on start managed workspace , it throws below error message. any one has seen this before?
View ArticleForum Post: RE: Can you disable synchronization of a class of P&ID components?
Hello Scott, We will check the possibilities. Can you also confirm the version of it? -Regards | Rahul Kumar
View ArticleForum Post: RE: Open plant Isometric manager error
Hello Rakhi, Can you try cleaning temp files. See below link for your help. HTH -Regards | Rahul Kumar
View ArticleForum Post: RE: Open plant Isometric manager error
Hi Rahul, thanks for the link and it fixed the problem. I did see this link but since error message was different was not sure if this will fix our issue. Thanks Rakhi
View ArticleWiki Page: To Show Continuing Components in OpenPlant Isometrics Manager
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64-bit) Area: OpenPlant Isometrics Manager Subarea: Iso-Generation Original...
View ArticleForum Post: Tagging and Annotation
Hello Bentley OpenPlant Users, We are in the process of gathering "typical" tag names and annotation formats for the upcoming OpenPlant CONNECT Edition Release. Here is your chance to help influence...
View ArticleForum Post: RE: Tagging and Annotation
Thanks Tony for this! I hope this relates to all OpenPlant Products. -Regards | Rahul Kumar
View ArticleForum Post: Upgrade AutoPlant SS6 projects to AutoPlant SS8
I am needing to Upgrade several AutoPlant SS6 (Version 8.11.11.135) projects to AutoPlant SS8 (Version 8.11.11.13.245). Is there documentation to follow outlining how to do this? We also have our SS8...
View ArticleForum Post: RE: Upgrade AutoPlant SS6 projects to AutoPlant SS8
Thanks for your query. I believe you may also need OpenPlant Isometrics Manager customised files to carry over? -Regards | Rahul Kumar
View ArticleWiki Page: [Microsoft][ODBC Excel Driver] too few parameters. Expected 2
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64bit) Area: Settings/Attributes Subarea: DBQuery Original Author:...
View ArticleWiki Page: How to Upgrade OpenPlant PID Schemas from Old Version to Latest...
Applies To Product(s): OpenPlant Project Administrator Version(s): 08.11.11.43 (SS6) | 08.11.11.223 (SS6 Refresh) Environment: Windows 7/8.1/10 (64 bit) Area: OpenPlant PID Workspace Subarea: Schema...
View ArticleForum Post: Is the an EC Expression to round to whole numbers in Class Editor
I would like to be able to bring up the Stud Diameter in our Item Descriptions. In the ASME catalog the STUD_DIA is in inches so in Class Editor we had multiplied that number by 25.4 to get it into...
View ArticleForum Post: RE: Is the an EC Expression to round to whole numbers in Class...
Hello Brynn, This should be able to be accomplished using System.Math Symbol Sets. To do this: Right click on the field Required ECExpression SymbolSets . Select to add a symbol set and enter in...
View ArticleWiki Page: Data Manager [FAQ]
Applies To Product(s): DataManager Version(s): All Environment: N/A Area: N/A Subarea: N/A Original Author: Bentley Product Advantage Group What is DataManager? Bentley Data Manager is a powerful...
View ArticleForum Post: RE: Is the an EC Expression to round to whole numbers in Class...
Brynn, An additional use of the System.Math.Round would be to round to a specific number of decimal places. This can be accomplished by the expression System.Math.Round(this.BOLT_DIA,1) . This will...
View ArticleForum Post: RE: Is the an EC Expression to round to whole numbers in Class...
Thanks Tony for this, You may also refer similar wiki articles describing similar situations: For Double type property, user should use custom attributes described in below wiki HTH -Regards | Rahul...
View ArticleForum Post: RE: Upgrade AutoPlant SS6 projects to AutoPlant SS8
Yes, help with this as well would be greatly appreciated
View ArticleForum Post: Openplant development support
Hi,Advanced Engineer: Where does the development resource get? Is it based on MDL development?how do I contact development technology support,?which teams in China openplant are doing?
View ArticleForum Post: RE: Openplant development support
Hello, You can directly write about it to product Management team. Please send you query to Abbas.ali@bentley.com or Rob.harper@bentley.com I am sure you will get some direction in this regard....
View Article