Forum Post: RE: Unable to use half coupling in open plant SS5

Thank you Harpreet. Currently I am using version 08.11.09.568 I tried with the procedure you provided but still the spec does not show half coupling while placing it. I have to place a coupling of size...

View Article


Forum Post: Unable to use auto plant instrument specs in open plant

I have tried to use (upgraded) the auto plant spec in open plant spec but while inserting the instrument no spec window pop up and no instrument can be added in the drawing. Regards, Jayant

View Article


Forum Post: RE: OPIM - Component is not connected to

Hello Stephane, As discussed the problem is because of line disconnection. use manual selection while generating isometric you will not get this error message. Hope this helps. Regards, Abhijit Bute

View Article

Forum Post: RE: OPIM - Component is not connected to

Hello Stephane, As discussed the problem is because of line disconnection. use manual selection instead of advance option while generating isometric you will not get this error message. Hope this...

View Article

Forum Post: RE: Autoplant Piping V8I - Isogen symbol modification

I'm not sure there is a way to combine the BI/ASC files. You may want to search the ISOGEN site to see if they have a utility to do it. The ** in FTFL are to let AutoPLANT PCF Export to put the correct...

View Article


Forum Post: RE: Unable to use auto plant instrument specs in open plant

Hi Jayant, Can you provide more details? Did you upgrade your AutoPlant Spec into OpenPlant Spec using Exchange process in OpenPlant Spec Gen? What class you are trying to place in OpenPlant Modeler?...

View Article

Forum Post: RE: Unable to use half coupling in open plant SS5

Thanks for confirming the version. In default configuration of OpenPlant Modeler there is no tool defined for HALF_PIPE_COUPLING so you need to follow the steps below: 1. Go to Utilities > Key-in....

View Article

Wiki Page: How to Show Dimension from Midpoint and Component Dimension as...

Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.470 (SS5), 08.11.11.87 (SS6) & Above Environment: Windows 7 (64 bit) & Others Area: Settings/Attributes Subarea:...

View Article


Wiki Page: How to Suppress Branch Dimensions by Size

Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.5XX(SS5) & 08.11.11.XX (SS6) Environment: Windows 7 (64 bit) & Others Area: Settings/Attributes Subarea: Isometric...

View Article


Wiki Page: Settings/Attributes- OpenPlant Isometrics Manager

To Discuss various settings desired to output Isometric drawings. See Index: Configuring the BOM and Reports Add End type Information in Isometric Bill of Material Cut list. Grouping of Supports Based...

View Article

Forum Post: RE: AutoPLANT SS7 integration with PW

Hello Stephane, AutoPLANT Modeler SS7 support PW SS4 (08.11.09.590) but do not support PW CE. However AutoPLANT Modeler SS7 Refresh/AutoPLANT Modeler SS8 does support PW CE. See image below: For more...

View Article

Wiki Page: How to present Nozzle Rating and Facing Information in OpenPlant...

Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX(SS5) Environment: Windows 7 (32/64-bit) & Others Area: Settings/Attributes Subarea: Schema- Custom attribute Original...

View Article

Forum Post: OPIM wrong dimension distance when a support exists

Good Day, The isometric generated by OpenPlant Isometrics manager, has the wrong distance number on the dimension. Here are the correct dimensions on the model: But in the generated Isometric, you can...

View Article


Forum Post: OpenPlant Special Interest Group Virtual Meeting on July 28 -...

Learn the latest New Features in OpenPlant Modeler and OpenPlant Isometrics Manager at this month’s virtual meeting of the OpenPlant Special Interest Group (SIG) on July 28 at 10:30 a.m. EDT. Please...

View Article

Forum Post: RE: OPIM wrong dimension distance when a support exists

Hello Luis, Can you please upload dwg file in below mentioned link so that we can check at our side and update you? Link to upload files: bentley.sharefile.com/r-rb8c2a0fd4dc43f0b Regards, Rajesh Agrawal

View Article


Comment on Readme file for OpenPlant Isometrics Manager V8i (SELECTseries 6)...

This file says when using with AutoPlant that it must be loaded along side AutoPlant Modeler SS8 or newer. Does anybody know when AutoPlant Modeler SS8 will be released?

View Article

Forum Post: RE: OPIM wrong dimension distance when a support exists

Hi Rajesh, I have uploaded the file as requested. Looking forward to your response. Thanks

View Article


Forum Post: Release Announcement - AutoPLANT V8i (SELECTseries 8) is LIVE now

Hello, The new AutoPLANT V8i (SELECTseries 8) 64-bit release is now available for downloaded from the Bentley Software Fulfillment site. The released AutoPLANT V8i (SELECTseries 8) Version 08.11.13.129...

View Article

Forum Post: RE: OPIM wrong dimension distance when a support exists

Hello Luise, This issue has been fixed in Openplant Isometrics Manager version "08.11.09.470". Please check with this build you will get the correct result. Hope this helps. Looking forward to your...

View Article

Comment on Readme file for OpenPlant Isometrics Manager V8i (SELECTseries 6)...

Hello Scott, To ensure your questions get proper attention, the best place to post is the respective forum. That said, I see a post from today announcing the SELECTseries 8 release of AutoPlant:...