Quantcast
Channel: OpenPlant | AutoPLANT
Browsing all 12277 articles
Browse latest View live
↧

Forum Post: RE: OPM SS6 - auto olets for Autoplant spec doesn't work

bump

View Article


Wiki Page: How to Calculate the Property Value With Help of EC Expression

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Component Subarea: Data Original Author: Harpreet Singh, Bentley...

View Article


Forum Post: RE: Calculated ECProperty adding two Double fields to be used in...

Hello Ray, I have created a wiki article for you which you can follow to get BOX_DISTANCE. I created a test property for this example and it works fine. Hope this helps! Regards, Harpreet

View Article

Wiki Page: Component - OpenPlant Modeler

Component- OpenPlant Modeler See Index: Add or Remove Fields from Spec Selection Dialog Delete/Replace the Flange Assembly in Open Plant Modeler How are Bolt Lengths Calculated in OpenPlant Modeler...

View Article

Forum Post: RE: How to show Tracing in OPM and OPIM

Thanks Ray, We have logged an Enhancement # 382891 based on SR # 7000562506 you have logged. This will further gets evaluated by product management team. HTH -Regards | Rahul Kumar

View Article


Forum Post: RE: OPM SS6 - auto olets for Autoplant spec doesn't work

Hello Tuan, sorry for delay in my response. I am still evaluating this. Will update on it shortly. HTH -Regards | Rahul Kumar

View Article

Forum Post: RE: OPM SS6 - auto olets for Autoplant spec doesn't work

Thanks Rahul

View Article

Forum Post: RE: How to identify pipeline/area/service in OPM by MVBA

Hi Think I tried to explain this shortly in your previous thread... I have solved this by customizing the project schemas by creating a property on each class(with the class editor) that I want to be...

View Article


Wiki Page: Component Preferences Dialogbox Does Not Appear On Screen After...

Applies To Product(s): AutoPLANT Version(s): 2004, XM, and V8i Environment: N/A Area: N/A Subarea: N/A Original Author: Bentley Technical Support Group Overview At some point, a user might find that...

View Article


Wiki Page: Attach OpenPlant Modeler Objects in ProSteel

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.564(SS5) | 08.11.11.87 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings\Attributes Subarea: - Original Author: Rahul Kumar,...

View Article

Forum Post: RE: Calculated ECProperty adding two Double fields to be used in...

As as extension to this, If a new field was added to the SPEC (PIPE_OD_M) and this was added to a Property in the Directional Pipe Guide (OUTSIDE_DIAMETER), the answer above will not work. Can you...

View Article

Forum Post: RE: Report OPM Model Name on the Isometric OPIM

This is for AutoPLANT not OpenPlant, and the answer seems to be how to change the ISO file format, not how to get the 3D model name from where the ISO was run onto the Isometric drawing sheet assigned...

View Article

Forum Post: RE: Calculated ECProperty adding two Double fields to be used in...

Can you please show the changes you have made in the schema for PIPE_OD_M? Is OUTSIDE_DIAMETER mapped with PIPE_OD_M field in schema? Regards, Harpreet

View Article


Wiki: AutoPLANT | AXSYS | OpenPlant | PlantWise Wiki

View Article

Forum Post: RE: Linking Elbows Supports to OpenPlant Physical Catalogue

Hi Ray, These supports are not spec driven, these are being drawn by code. Please create an SR for this and we will log enhancement for it. Regards, Harpreet

View Article


Forum Post: OPM/OPIM SS6 Split iso into 1 sheet per spool

Hi, Just want to ask is there any way to auto split an Iso drawing (1 drawing number) into multiple sheets with 1 sheet/spool. I can manually do it by placing Iso Break at each flange connection, but...

View Article

Forum Post: RE: OPIM - Rotated dimension?

Hello Magie, I believe you got answer about this issue in other your thread: communities.bentley.com/.../384568 I hope this information will be useful. Please let me know if you need additional help on...

View Article


Forum Post: RE: OPM/OPIM SS6 Split iso into 1 sheet per spool

Hello Tuan, Auto Splitting can be done. Currently splitting can be done based on attributes, Split on component count. Check Below wiki for reference. However spool wise isometric is not supported with...

View Article

Forum Post: autocad user needing object enabler for autoplant AT_REBOIDS

greetings everyone....I received some older cad files that are referencing "AT_REBOIDS" on some of the fittings/pipe. Is there an object enabler that will allow my cad dwgs to be view correctly? Right...

View Article

Forum Post: RE: autocad user needing object enabler for autoplant AT_REBOIDS

Hello Mike, Check below forum thread for reference. HTH -Regards | Rahul Kumar

View Article
Browsing all 12277 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>