Browse latest View live
↧

Forum Post: RE: OPM/OPIM SS6 Split iso into 1 sheet per spool

Thanks Rahul, any word on CONNECT time frame for OpenPlant family?

View Article


Forum Post: RE: OPM SS6 - auto olets for Autoplant spec doesn't work

another bump on this one

View Article


Forum Post: RE: OPM SS6 - auto olets for Autoplant spec doesn't work

Hello Tuan, Sorry on this. I just checked the case. For auto Olets entries, you need to add the Branch code to Branch table. See below wiki for adding branch table entries and information on branch...

View Article

Forum Post: RE: autocad user needing object enabler for autoplant AT_REBOIDS

great. Thanks very much. Not perfect display, but WAY better than before the enabler was installed! MKH

View Article

Forum Post: RE: OPM SS6 - auto olets for Autoplant spec doesn't work

Hi Rahul, So I have to convert AT spec to OPM spec for the olets to work properly? Attached is the supplied catalog for the test spec. Both branch code and branch table have been properly declared I...

View Article


Forum Post: Slip on joint in weld report in OPM

How can I extract the slip on joint quantity in weld report? In addition to this how can I generate a report that quantify the total size wise welds in a particular pipe line? Regards, Jayant Thakur

View Article

Wiki Page: How to Compress Welds for Slip On Flange

Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: Original Author: Rahul...

View Article

Forum Post: RE: Slip on joint in weld report in OPM

Hello Jayant, You can try below wiki link as reference where reports based on weld types has been extracted. You may also refer other similar wiki on weld reporting. Also there is a report type to...

View Article


Forum Post: RE: OPM/OPIM SS6 Split iso into 1 sheet per spool

Hello Tuan, It is currently under development. No fixed date yet but you expect the good news soon. HTH -Regards | Rahul Kumar

View Article


Forum Post: RE: Calculated ECProperty adding two Double fields to be used in...

Hi Harpreet, This need to do this as the support pipe guide requires to have clearance from the OD of the pipe not the nominal diameter. After doing the modifications below, the calculation for the...

View Article

Forum Post: RE: OPM SS6 - auto olets for Autoplant spec doesn't work

Hi, Just wanna bump this so I can keep track

View Article

Forum Post: OPM - Flexible Hose reading the Piping Spec

Hi All, I'm sorry if this has already been asked, but I was unable to find anything apart from AutoPLANT answers on Flexible hoses. In OpenPlant Modeler I have been unsuccessful in placing a flexible...

View Article

Forum Post: RE: Linking Elbows Supports to OpenPlant Physical Catalogue

SR 7000564224 created

View Article


Forum Post: RE: OPM SS6 - auto olets for Autoplant spec doesn't work

Hello Tuan, Have you tried converting your AT specs to OPM format using the Specgen Exchange Utility? This will update class names for all mapped components. Here is an article with detailed steps on...

View Article

Forum Post: RE: Calculated ECProperty adding two Double fields to be used in...

Hi Ray, I see you have added OUTSIDE_DIAMETER on DIRECTIONAL_PIPE_GUIDE class in OpenPlant_Catalogue schema. It should be a spec field instead of EC Property here. So, please change OUTSIDE_DIAMETER to...

View Article


Forum Post: RE: Linking Elbows Supports to OpenPlant Physical Catalogue

Thanks for the SR. Will get back to you with the number soon. Regards, Harpreet

View Article

File: OPM-Example Spec

View Article


Forum Post: RE: OPM - Flexible Hose reading the Piping Spec

Hi Ray, Please download the spec file from below link. Let me know if it works for you. Regards, Harpreet

View Article

Forum Post: OPIM SS6 - Flatten to 2D

Hi, I thought this was going to a straight forward setting switch, but doesn't seem like it. First of all, can OPIM generate flattened isometric drawings directly? If not, is there some sort of...

View Article

Forum Post: RE: OPIM SS6 - Flatten to 2D

Hi Tuan, Please refer section To Publish 2D DGN file as Default Isometrics (With OpenPlant Isometrics Manager SS6 Only) in below wiki article Hope this helps! Regards, Harpreet