Browsing all 12277 articles
Browse latest View live
↧

Forum Post: RE: Calculated ECProperty adding two Double fields to be used in...

Thanks Harpreet, The value is now working, thanks I understand how it works now. The only issue now is that it has no affect on the drawing of the support. Directional Pipe Guide, I'm not sure if out...

View Article


Forum Post: RE: OPIM SS6 - Flatten to 2D

Thanks Harpreet, I'll give that a go.

View Article


Forum Post: OPM SS6 - best component template for push fit/crimped connections

Hi, Just wondering which component templates that I can base on for creating push-fit/crimped components in OPM SS6? From the delivered catalogs and spec, I can only see the following end/facing type:...

View Article

Forum Post: OPM / OP SpecGen SS6 - Field values reference table

Hi, Any chance I can obtain a reference document that lists all the acceptable values for each fields in a spec/catalog database? And the description for each value, both for OPM and AutoPlant? I would...

View Article

Forum Post: RE: OPM SS6 - best component template for push fit/crimped...

Further to this, I found this wiki article which shed some light on push fit end conditions. Hopefully that's all I need. communities.bentley.com/.../21149.openplant-end-condition-long-descriptions

View Article


Forum Post: RE: OPM / OP SpecGen SS6 - Field values reference table

Oh, and while we're here. It would be handy if there's a description of each spec/field's expected datatype as well.

View Article

Forum Post: OPIM SS6 - Startup config switches

Hi, Just seek to clarify, from what I've seen OPIM doesn't have the ability to be customized using startup config switches like Microstation or AECOSim (for example -wp, -wu, -wi etc.), is that...

View Article

Forum Post: RE: OPIM SS6 - Startup config switches

Hello Tuan, You can use shared network drive for configurations. Also can define isometrics output at shared location. See below wiki articles for reference. Also can check other related articles...

View Article


Forum Post: RE: OPM SS6 - best component template for push fit/crimped...

Yes Tuan, You can also take a hint from Help file menu. Article mentioned here is also same. Please let us know if specific type you wanted to implement as a default content inside OpenPlant Modeler....

View Article


Forum Post: RE: OPIM SS6 - Startup config switches

Hi Rahul, I've got OP Modeller pointed to network workspace no problem. Normally, for our CAD builds, I'll leave the standard installation untouched and create custom startup shortcuts that's using...

View Article

Wiki Page: Field Reference Description in OpenPlant Modeler

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: OpenPlant Specification Generator Subarea: - Original Author:...

View Article

Forum Post: RE: OPM / OP SpecGen SS6 - Field values reference table

Hello Tuan, You may check below wiki article for your ready Reference. This also contains inside Help File menu. HTH -Regards | Rahul Kumar

View Article

Forum Post: RE: OPM SS6 - best component template for push fit/crimped...

Hi Rahul, I'm glad you asked. which end condition I can use for electrofusion connections? PS: is PSW - Plastic socket weld an appropriate use? Best regards, Tuan Le

View Article


Forum Post: RE: OPM SS6 - best component template for push fit/crimped...

Hello Tuan, The article mentioned above explains the default values present inside OpenPlant Modeler. However there are few types which you may also customize it for your project unless any specific...

View Article

Forum Post: RE: OPIM SS6 - Startup config switches

Hello Tuan, You can check below wiki as well where whole workspace can be shared through network drive. HTH -Regards | Rahul Kumar

View Article


Forum Post: RE: OPM SS6 - auto olets for Autoplant spec doesn't work

(Please visit the site to view this file)Hi Mehreen, Attached are the 2 spec files that I've tried using your method. The AT_Test.mdb is the upgraded AutoPlant spec (using "Upgrade to OPM" function),...

View Article

Forum Post: RE: OPM SS6 - best component template for push fit/crimped...

Well, I can't thank you enough Rahul. Exactly what I'm looking for. Cheers.

View Article


Forum Post: How to customize OPM properties?

Hello All, For example, there is a property "OUTSIDE_DIAMETER" for pipe, but it always be 0. The outside diameter did exist, otherwise the pipe cannot be placed. How to fill the OD value in the...

View Article

Forum Post: RE: How to customize OPM properties?

I have found it. Thanks a lot! communities.bentley.com/.../26067.how-to-map-spec-field-with-openplant-modeler-property

View Article

Forum Post: RE: How to customize OPM properties?

Hi Changsong, This is happening because Outside Diameter is not mapped with spec field. Please refer below wiki article to map the property. Hope this helps! Regards, Harpreet

View Article