Forum Post: RE: Calculated ECProperty adding two Double fields to be used in...
Thanks Harpreet, The value is now working, thanks I understand how it works now. The only issue now is that it has no affect on the drawing of the support. Directional Pipe Guide, I'm not sure if out...
View ArticleForum Post: OPM SS6 - best component template for push fit/crimped connections
Hi, Just wondering which component templates that I can base on for creating push-fit/crimped components in OPM SS6? From the delivered catalogs and spec, I can only see the following end/facing type:...
View ArticleForum Post: OPM / OP SpecGen SS6 - Field values reference table
Hi, Any chance I can obtain a reference document that lists all the acceptable values for each fields in a spec/catalog database? And the description for each value, both for OPM and AutoPlant? I would...
View ArticleForum Post: RE: OPM SS6 - best component template for push fit/crimped...
Further to this, I found this wiki article which shed some light on push fit end conditions. Hopefully that's all I need. communities.bentley.com/.../21149.openplant-end-condition-long-descriptions
View ArticleForum Post: RE: OPM / OP SpecGen SS6 - Field values reference table
Oh, and while we're here. It would be handy if there's a description of each spec/field's expected datatype as well.
View ArticleForum Post: OPIM SS6 - Startup config switches
Hi, Just seek to clarify, from what I've seen OPIM doesn't have the ability to be customized using startup config switches like Microstation or AECOSim (for example -wp, -wu, -wi etc.), is that...
View ArticleForum Post: RE: OPIM SS6 - Startup config switches
Hello Tuan, You can use shared network drive for configurations. Also can define isometrics output at shared location. See below wiki articles for reference. Also can check other related articles...
View ArticleForum Post: RE: OPM SS6 - best component template for push fit/crimped...
Yes Tuan, You can also take a hint from Help file menu. Article mentioned here is also same. Please let us know if specific type you wanted to implement as a default content inside OpenPlant Modeler....
View ArticleForum Post: RE: OPIM SS6 - Startup config switches
Hi Rahul, I've got OP Modeller pointed to network workspace no problem. Normally, for our CAD builds, I'll leave the standard installation untouched and create custom startup shortcuts that's using...
View ArticleWiki Page: Field Reference Description in OpenPlant Modeler
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: OpenPlant Specification Generator Subarea: - Original Author:...
View ArticleForum Post: RE: OPM / OP SpecGen SS6 - Field values reference table
Hello Tuan, You may check below wiki article for your ready Reference. This also contains inside Help File menu. HTH -Regards | Rahul Kumar
View ArticleForum Post: RE: OPM SS6 - best component template for push fit/crimped...
Hi Rahul, I'm glad you asked. which end condition I can use for electrofusion connections? PS: is PSW - Plastic socket weld an appropriate use? Best regards, Tuan Le
View ArticleForum Post: RE: OPM SS6 - best component template for push fit/crimped...
Hello Tuan, The article mentioned above explains the default values present inside OpenPlant Modeler. However there are few types which you may also customize it for your project unless any specific...
View ArticleForum Post: RE: OPIM SS6 - Startup config switches
Hello Tuan, You can check below wiki as well where whole workspace can be shared through network drive. HTH -Regards | Rahul Kumar
View ArticleForum Post: RE: OPM SS6 - auto olets for Autoplant spec doesn't work
(Please visit the site to view this file)Hi Mehreen, Attached are the 2 spec files that I've tried using your method. The AT_Test.mdb is the upgraded AutoPlant spec (using "Upgrade to OPM" function),...
View ArticleForum Post: RE: OPM SS6 - best component template for push fit/crimped...
Well, I can't thank you enough Rahul. Exactly what I'm looking for. Cheers.
View ArticleForum Post: How to customize OPM properties?
Hello All, For example, there is a property "OUTSIDE_DIAMETER" for pipe, but it always be 0. The outside diameter did exist, otherwise the pipe cannot be placed. How to fill the OD value in the...
View ArticleForum Post: RE: How to customize OPM properties?
I have found it. Thanks a lot! communities.bentley.com/.../26067.how-to-map-spec-field-with-openplant-modeler-property
View ArticleForum Post: RE: How to customize OPM properties?
Hi Changsong, This is happening because Outside Diameter is not mapped with spec field. Please refer below wiki article to map the property. Hope this helps! Regards, Harpreet
View Article