Hi, AutoPLANT SS7r1 (.239) AutoPLANT i-model Composer (.129) ProjectWise SS4 (.590) Navigator Connect (6.1.1.52) I'm trying to view an i-model created from a piping model. Navigator shows error message...
View ArticleForum Post: Intelligent Line Manager Default settings
I am experimenting with the Intelligent Line Manager command in both SS5 and SS6. The command always opens with the corner option as Pipe Bend, which is not what our industry would most commonly use....
View ArticleForum Post: RE: Intelligent Line Manager Default settings
Hi Richard, It looks like we don't have an option to change the default setting for corner in Intelligent Line Manager. However, we are still looking into it and will get back to you ASAP. Regards,...
View ArticleWiki Page: Cannot activate PlantSpace Piping license
Product(s): Bentley PlantSpace Piping Version(s): 08.09.04.52 Environment: N\A Area: Licensing - Technical Subarea: N\A Problem My PlantSpace Piping license no longer activates, even though I have not...
View ArticleForum Post: RE: OPM - Flexible Hose reading the Piping Spec
Hi Harpreet, I was hoping to get the Flanged Hose working, did you have any idea's as to what I need to do to make it work? Ray
View ArticleForum Post: RE: AutoPLANT i-model, which Navigator version
Navigator CONNECT Edition Update 3 (06.01.01.52) no longer supports version 05 i-models (*.imodel), that requires version 06 i-models (*.imodel) The 05 i-models were used by previous versions of...
View ArticleWiki Page: Isometric Fails with “Error [0]: Unable to Locate ADDON (4) to...
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: Original Author:...
View ArticleForum Post: RE: 2D Valve Symbols When cutting dynamic views
Hello, Sorry for this delay, In AECOsim, you have the option for using Mechanical Drawing Rules which can substitute the 3D symbol for a 2D Plan Symbol Cell in the dynamic view. OpenPlant Modeler is a...
View ArticleWiki Page: OpenPlant Reporting
OpenPlant Reporting OpenPlant Reporting is an OpenPlant application which provides an interface to generate reports from either the OpenPlant Modeler application, or as a Standalone application...
View ArticleWiki Page: How to Remove Prefix and to Show Equipment Name with Nozzle...
Applies To Product(s): OpenPlant Orthographics Manager Version(s): 08.11.11.87 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings Subarea: Annotations Original Author: Faisal Khan, Building...
View ArticleForum Post: RE: OPM - Flexible Hose reading the Piping Spec
Hi Ray, You just need to add Flexible Hose in your spec which has FL as end conditions. Please see below snapshot of the spec. Highlighted the fields which I modified. Below is the snapshot from the...
View ArticleForum Post: RE: AutoPLANT i-model, which Navigator version
Hello Stephane, Darius is right. I have tested one of your provided testing models in same environment and with earlier Navigator CONNECT Edition version AutoPLANT i-models works perfectly. Check...
View ArticleForum Post: RE: OPM - Flexible Hose reading the Piping Spec
I placed one hose, and then run an ISO, but get an error on creating the Isometric Error[0] no DEF entry for scaler type FLEX2 Any idea why it would be saying this? In the schema the HOSE - Isometric...
View ArticleForum Post: RE: OPM - Flexible Hose reading the Piping Spec
Looks like that definition for FLEX2 is missing in symbolsize.def file of your style. Open symbolsize.def file from your style's config folder in notepad and add below values as highlighted. Looking...
View ArticleForum Post: AutoPlant Model File Errors - Need Help To Resolve
Hello, The piping model I was updating unexpectedly received errors when launching AutoPlant. I was using AutoPlant without any issues one minute, closed down the model to rerun the Navisworks file and...
View ArticleForum Post: RE: AutoPlant Model File Errors - Need Help To Resolve
Hello David, Thanks for posting your query to Plant forum! Can you please recheck the images you have attached here? It is not visible at our side. Also Please mention Product version details to enable...
View ArticleForum Post: RE: AutoPlant Model File Errors - Need Help To Resolve
(Please visit the site to view this file) AutoPlant v8i ss4 version 08.11.09.140 Thanks!! Phil.
View ArticleForum Post: AutoPLANT Modeler, Lined Pipe, Bolt Calculation
Hi, AutoPLANT Modeler SS7r1 (.239) Lined Pipe Module Bolt calculation is not done when inserting two fittings. Works fine when something is in between the flanges. Calculated Bolt Length is set to Yes SH
View ArticleForum Post: system Requeriments
hello. I would like to know the requirements of my system to install autoplant
View ArticleForum Post: RE: OPM - Flexible Hose reading the Piping Spec
HI, I didn't have any of the lines for FLEX in this file. Above is what I've added, no header or anything, and now I get the error above. Ray