Forum Post: OPM - Pipe Insulation Saddle adjust angle

Hi, Is there a way to control the angle of wrap around the pipe with this kind of support? It seems to be hard set to 90deg, I would like to have the ability to increase/decrease this. Thanks Ray

View Article


Forum Post: RE: system Requeriments

Hello Andres, Could you please let me know the version of AutoPLANT? So that i can guide you proper direction. Looking forward to your reply. Regards, Abhijit Bute

View Article


Forum Post: RE: AutoPLANT Modeler, Lined Pipe, Bolt Calculation

Hello Stephane, Could you please attach some example. Also please refer following blog regarding bolt calculation. communities.bentley.com/.../how-are-bolt-lengths-calculated-in-autoplant-piping...

View Article

Forum Post: RE: OPM - Pipe Insulation Saddle adjust angle

Hi Ray, You can adjust the angle while placement also after the placement by using the manipulators as shown below: Did you try it? Regards, Harpreet

View Article

Forum Post: RE: OPM - Pipe Insulation Saddle adjust angle

Hello Ray, Believe this could be logged as an Enhancement. We will Confirm the number soon. -Regards | Rahul Kumar

View Article


Wiki Page: Bentley AutoPLANT

Bentley AutoPLANT Plant Design Workgroup A solution for innovative 3D modeling and detailed design Bentley AutoPLANT Plant Design is an object-based 3D piping design and modeling application that runs...

View Article

Comment on Which is the latest version of AutoPLANT® Modeler?

Hello Juan, This situation was reported as defect and already has been fixed in AutoPLANT V8i (SELECTseries 7) Refresh release. Compatible version is ProStructures V8i (SELECT series 6) for AutoCAD...

View Article

Wiki Page: Which is the latest version of AutoPLANT® Modeler?

Applies To Product(s): AutoPLANT Modeler Version(s): Environment: N/A Area: Subarea: N/A Original Author: Keith Couvillion, Bentley Product Advancement Group Which is the latest version of AutoPLANT®...

View Article


Wiki Page: Who uses AutoPLANT® Modeler?

Applies To Product(s): AutoPLANT Modeler Version(s): Environment: N/A Area: Subarea: N/A Original Author: Keith Couvillion, Bentley Product Advantage Group Who uses AutoPLANT® Modeler? Engineers,...

View Article


Wiki Page: What is AutoPLANT® Modeler?

Applies To Product(s): AutoPLANT Modeler Version(s): Environment: N/A Area: Subarea: N/A Original Author: Keith Couvillion, Bentley Product Advantage Group What is AutoPLANT® Modeler? AutoPLANT®...

View Article

Wiki Page: AutoPLANT project versions and Bentley® OpenPlant Isometrics Manager

Applies To Product(s): AutoPLANT Modeler Version(s): Environment: N/A Area: Subarea: N/A Original Author: Keith Couvillion, Bentley Product Advantage Group Which AutoPLANT project versions are...

View Article

Wiki Page: AutoPLANT Modeler V8i Enhancements

Applies To Product(s): AutoPLANT Modeler Version(s): SS5 | SS6 | SS7 | SS8 Environment: Windows 7/8.1/10 (64 bit) Area: AutoPLANT Modeler [FAQ] Subarea: Original Author: Kestutis Mitkus, Bentley...

View Article

Forum Post: RE: system Requeriments

Hello Andres, Different AutoPLANT versions has different System Requirements, so you need check AutoPLANT ReadMe. Here are AutoPLANT ReadMe links in which you can check what are System Requirements for...

View Article


Forum Post: RE: OPM - Pipe Insulation Saddle adjust angle

Hi Ray, I would like to inform you that this issue resulted in Enhancement Request # 486610 . We are continuously improving our products via regular SELECT updates, during which we implement many of...

View Article

Wiki Page: Bentley® AutoPLANT® Modeler V8i ReadMe

Applies To Product(s): AutoPLANT Modeler Version(s): V8i | SS1 | SS2 | SS3 | SS4 | SS5 | SS6 | SS7 | SS8 Environment: Windows 7/8.1/10 (64 bit) Area: AutoPLANT Modeler [FAQ] Subarea: Original Author:...

View Article


Forum Post: RE: AutoPLANT Modeler, Lined Pipe, Bolt Calculation

When placing 2 * 4” dim. flanged elbows having a flange thickness of 3 inches, Bolts still have the default spec bolt length, 3 1/2”. When placing 2 * 4” dim. flanged elbows having a flange thickness...

View Article

Forum Post: RE: OPM - Flexible Hose reading the Piping Spec

HI Harpreet, Found the issue, it was the cell library lisocomp.cel, it didn’t have the FLEX2 and FLEX1 cells.I've updated the Cell library to include both of these and it now produces an ISO the same...

View Article


Wiki Page: How to show all Supports with Same Isometric Symbol in Generated...

Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX(SS5), 08.11.11.xx (SS6) Environment: Windows 7 (64 bit) & others Area: Settings/Attributes Subarea: Isometric Cells...

View Article

Forum Post: RE: OPM - Flexible Hose reading the Piping Spec

Hello Ray, For any cell error type messages you should check the project cell file i.e. lisocomp.cel which is a default library. You may edit the FLEX type in under cell dialog using right click "Open...

View Article

Forum Post: RE: AutoPLANT - Assembly Manager - Crash on insert

Hello Stephane, I would like to inform you that this issue was logged as Defect Report 352219, and it is already fixed in newest AutoPLANT Modeler SS8 version 8.11.13.129. Regards, Kestutis Mitkus

View Article