Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.10.564 (SS5) Environment: Windows 7/8.1/10 (64 bit) Area: ProjectWise Interoperability Subarea: Original Author: Harpreet Singh, Bentley Product Advantage Group Problem Description User getting below error when launching OpenPlant Isometrics Manager with Managed Workspace and OpenPlant ModelServer. Reason This error occurs mainly when the server schemas have been updated and after that user tries to login to the OpenPlant Isometrics Manager. It actually fails to login to OpenPlant ModelServer because there is a conflict of server schemas and local schemas in C:\Users\%UserName%\AppData\Roaming\Bentley\OPIM\%ProjectName%\Schema. Steps to Resolve Delete the OPIM folder from the location C:\Users\%UserName%\AppData\Roaming\Bentley\ Note: This error should not have occurred therefore defect has been logged for this issue in our backlog. Still a Problem If there is still some problem and you cannot connect to OpenPlant Isometrics Manager after trying the above suggestion, then please create a Service Request and contact Bentley Product Advantage group along with the list of all relevant details to get in depth analysis and for possible solution or workarounds. Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!
↧