Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.564 (SS5) Environment: Windows 7/8.1/10 (64 bit) Area: ProjectWise Interoperability Subarea: Original Author: Harpreet Singh, Bentley Product Advantage Group Problem Description Below error shows up when loading I-model from Projectwise managed workspace in OpenPlant Isometrics Manager. This error message usually appears when I-model is loaded from different location than default location. Steps to Resolve Launch Projectwise Administrator. Login to the datasource and go to Workspaces>Managed>Project. Select the project CSB and add below variable into the configuration block. OPIM_IMODEL_DIRECTORY Set the projectwise path in the value. It should point to the folder where I-models have to be loaded from. Save the changes and re-launch OpenPlant Isometrics Manager with Managed Workspace. Load the I-model from the defined folder. Still a Problem If there is still some problem and you cannot connect to OpenPlant Isometrics Manager after trying the above suggestion, then please create a Service Request and contact Bentley Product Advantage group along with the list of all relevant details to get in depth analysis and for possible solution or workarounds. See Also Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!
↧