Forum Post: RE: Olet problem in OpenPlant

$
0
0
Hello Changsong, Please see below response. For AutoBranch Table - I believe you are testing it with DN100 size. Using Auto Branch table, length exceeding twice the diameter (i.e. 114.3x2 = 228.6 ~229) will work. Falling below value will not allow to place. As a workaround, you should try placing manually for those lengths. This is a known issue. You can log a service request to enable us to log an enhancement to prioritize it. Generation of iso sheet manually - you should only join same pipeline for one common iso-sheet. Try with one pipeline for both header branch placement. It will generate one common sheet. HTH, -Regards | Rahul Kumar