Hi, I'm trying to define our work flow for OPM at the moment and I've found something I would call a bug in OPM SS6. Due to the size of our piping model, I've determined it's best to have each pipeline in its own model. So essentially, in a design file, there'll be multiple models. Each model will have 1 pipeline defined and modelled in it. For example, say my DGN file has 2 models: A and B. Model A has pipeline X defined and modelled inside it, and model B has the definition and model for pipeline Y. So when I switch between model from A to B, I would expect the standard preferences dialog to update the pipeline list accordingly in its dropbox. However, that's not the case, the standard preferences dialog still has pipeline X as the active pipeline. Meaning now I'm in model B and the active pipeline is still X. So when I proceed to place any piping component, an error message would show up. The component can still be placed, but it is now assigned to the pipeline X, instead of Y, and hence doesn't appear in the Pipeline Manager dialog, which only shows pipeline Y as is the case for model B. Below is the snapshot of the error message. So everytime I switch models, I have to restart the standard preferences dialog, which is really a drag. Can someone from Bentley take a look at this and advise if there's anyway to fix this bug for SS6? I can confirm that this is reproducible in standard OPM build using Bentley delivered spec. Best regards, Tuan Le
↧