Forum Post: RE: How to get flow direction arrow on isometric in OPM?

This issue is know to us and it is in our backlog. Unfortunately, this formula is not configurable through schema. This is being drawn by the script. Regards, Harpreet

View Article


Forum Post: RE: OPIM command line arguments

Ohh so then the command line arguments is pretty much useless when using a PW workspace. I understand that we need to specify what project pcf/schemas and such we are going to use. Otherwice OPIM...

View Article


Forum Post: RE: openplat modeler- structural

Hi, could you please help me and tell me where can I find the tool to make ladders, satirs and handrail in OPM? Thank you, Elena

View Article

Forum Post: RE: spectacle blind does not connect with flange

Hi Souren, You are right, adding this joint validation script on WAFER_JOINT should also work. Regards, Harpreet

View Article

Wiki Page: How To Add Custom Property in Pipeline Tag

Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX & Higher Environment: Windows 7/8/10 (64 bit) Area: Customization Subarea: Original Author: Deepak Singh, Bentley Product Advantage...

View Article


Wiki Page: OPPID - Tag Expression and results

Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Customization Subarea: Tag Original Author: Steven Morrow Background...

View Article

Wiki Page: How to Add Properties to Flow Flag Annotation in KKS Project

Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Customization Subarea: KKS Original Author: Harpreet Singh, Bentley...

View Article

Forum Post: RE: AutoPLANT SS8 - How to order the list of Specs in the Dropdown?

Hello Ray, I am checking with default project, and I can see the spec are order from A to z. Are you getting different result? Please share the screen shot so that it will help us to understand your...

View Article


Forum Post: Horizontal angle tolerance minimum for isometrics to show hatching

We have a project that has a pipe which is routed horizontally with a very small angle from the X axis. While the run of pipe is long enough to have a six inch offset, the overall angle from the X axis...

View Article


Forum Post: RE: AutoPLANT SS8 - How to order the list of Specs in the Dropdown?

Sure, I've tested a few things and I can't work out why its showing them in a different order. The specs are a mix of Access 2000 and 2003 If I point the Metric default project to my set of specs on a...

View Article

Forum Post: Some issues of Custom Equipment on OpenPlant Orthographics Manager

Hey guys: When I was trying to get Plan drawings from OPOM, here is it, Well, we got 3 pieces of Equipment here: 1, The First from top, a parametric horizontal vessel which is reserved by...

View Article

Forum Post: RE: spectacle blind does not connect with flange

It works Harpreet, thanks regards

View Article

Forum Post: RE: Horizontal angle tolerance minimum for isometrics to show...

Hi Richard, Which version of OpenPlant Isometrics Manager you have? I tested this with OpenPlant Modeler 08.11.11.96 + OpenPlant Isometrics Manager 08.11.11.103 and I am getting the correct result as...

View Article


Wiki Page: How to Show Nozzle Elevation in Report

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Component Subarea: Report Original Author: Deepak Singh,...

View Article

Forum Post: RE: Some issues of Custom Equipment on OpenPlant Orthographics...

Hi Joe, For point 2, It is taking the dimensions from origin point. For Point 3, How did you create custom class? It looks like, class doesn't have the all properties. Regards, Harpreet

View Article


Wiki Page: "Error: = 1603" While Installation of OpenPlant Isometrics Manager

Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Installation Subarea: Original Author: Harpreet...

View Article

Wiki Page: "{SERVICE_IS_RELATED_TO_EQUIPMENT(VG.0000003279)} belongs to the...

Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Installation-Configuration Subarea: Database Original Author:...

View Article


Forum Post: OPM SS6 - Standard preferences error when working with multiple...

Hi, I'm trying to define our work flow for OPM at the moment and I've found something I would call a bug in OPM SS6. Due to the size of our piping model, I've determined it's best to have each pipeline...

View Article

Wiki Page: Error: "Connection Test Failed" While Mapping SQL Database to...

Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Installation-Configuration Subarea: Database Original Author:...

View Article

Forum Post: RE: OPM SS6 - Standard preferences error when working with...

Hi Tuan, Unfortunately, we do not support multiple models in the DGN file in OpenPlant Modeler. If you want to break the model, then you will have to create separate DGN file and then attach it as a...