Forum Post: RE: OPPID
Hello Nuno, Can you please refer below wiki link. HTH Regards | Jaya
View ArticleForum Post: RE: OPPID
Thanks Jaya but i already did that, the only problem is when i insert the pipe component, hand valves or control valves etc... it change the weight line of one side.
View ArticleForum Post: RE: OPPID
Hello Nuno, If you have added service to Valve class and this Hand Valve is working differently, then check if this Hand Valve class already has additional configurations, which are changing line...
View ArticleForum Post: RE: COORDINATES NORTH, EAST, ELEVATION in OPEN PLANT MODELER?
Hi Jaya, Thank you for helping me. I am receiving this error when I am doing the connectivity checker. Could you please tell me what does it mean? See the end of this message for details on invoking...
View ArticleForum Post: RE: OPPID
Thank you Kestutis, the thing is that does the same to any pipe component, add i try not chose any service when i draw the pipe and that works fine, the valve as already this line weight before. See...
View ArticleForum Post: RE: COORDINATES NORTH, EAST, ELEVATION in OPEN PLANT MODELER?
Hello Elena, Please log a Service Request for the issue. And attach all necessary information for investigation like sample files and the images of the error message. Regards | Jaya
View ArticleWiki Page: How To Create and Populate Service Description Property on Piping...
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Properties Subarea: Original Author: Kestutis Mitkus, Bentley...
View ArticleWiki Page: OpenPlant Isometrics Manager
Generate intelligent isometrics from multiple sources Piping isometric drawings are among the most important deliverables from plant designs. Bentley OpenPlant Isometrics Manager V8 i is the first...
View ArticleWiki Page: OpenPlant Orthographics Manager
Faster, Higher-quality General Arrangement Drawings OpenPlant Orthographics Manager V8i automates the extraction and production of high-quality general arrangement plant drawings from a 3D model,...
View ArticleWiki Page: OpenPlant Support Engineering
OpenPlant Support Engineering OpenPlant Support Engineering (OPSE) is an application which will provide complex design and Modeling of Support for Piping, Structural, Electrical and HVAC Components....
View ArticleWiki Page: OpenPlant Project Administrator
OpenPlant Project Administrator Available on Select:- OpenPlant Project Administrator V8 i (SELECTseries 5) 08.11.09.415 OpenPlant Project Administrator V8 i (SELECTseries 6) Refresh 08.11.11.225 See...
View ArticleBlog Post: Tech Talk: Reducing Brownfield Design Costs of Water and...
Join Bentley senior solution consultant, Shaun Severin, to discuss how you can reduce costs and project time by utilizing reality modeling on your next brownfield water or wastewater treatment plant...
View ArticleWiki Page: OpenPlant ModelServer
Plant Design Collaboration and Project Management Software OpenPlant ModelServer V8 i is the first plant design server software to effectively and productively manage and distribute plant design...
View ArticleWiki Page: How to Update Attributes in Title Block in OpenPlant Isometrics...
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.11.224 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes Subarea: Text and Annotation Settings Original...
View ArticleWiki Page: Settings/Attributes - OpenPlant Isometrics Manager
To Discuss various settings desired to output Isometric drawings. See Index: For OpenPlant Modeler - OpenPlant Isometrics Manager Configuring the BOM and Reports Add End type Information in Isometric...
View ArticleWiki Page: How to get Line Tag Info for PRV in Data Manager
Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Data Manager Subarea: Customization Original Author: Jaya Tiwari,...
View ArticleForum Post: Text annotation components with services oppid
Hello, I add services to my components, equipments and pipeline, works fine. The only problem is that i want to add The TAG of the component to the same service. Can anyone help? Thank you The result...
View ArticleForum Post: RE: Text annotation components with services oppid
Hello Nuno, Do you want to apply same Tag of Valve to the the Service?. However, you can also refer below wiki link. Regards | Jaya
View ArticleForum Post: RE: Text annotation components with services oppid
Yes, the same tag as the component valve or fitting or equipement.
View ArticleWiki Page: How to Place Various Types of Flanges Automatically for Component...
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Component Subarea: Graphics Original Author: Rahul Kumar,...
View Article