Wiki Page: How to import Unit, Service, Pipeline Instances from a Text File...
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Tasks Subarea: Piping Original Author: Justinas Lipnickas,...
View ArticleForum Post: RE: How to fill pipeline attributes in batch
Thanks a lot! But it seems to imput service/pipeline/area/etc, I have the them already. I need to fill temp/press value for each pipeline, can it do it?
View ArticleForum Post: RE: How to fill pipeline attributes in batch
Hi Changsong, Yes, you can add Temperature and Pressure values the same way under Instance Data header and import the file. Make sure the property names match with ECProperty in schemas. Regards, Harpreet
View ArticleForum Post: RE: How to fill pipeline attributes in batch
I did test, it can used to import new pipelines, cannot revise existing pipelines. I want to revise them.
View ArticleForum Post: RE: How to fill pipeline attributes in batch
Yes, it prompts for the existing pipelines and therefore does not revise them. However, if you modify any instance (which is part of the pipeline tag) it would create new pipeline. Could you please...
View ArticleForum Post: RE: How to fill pipeline attributes in batch
Be honest, I have never seen any application provided a tool to revise existing attributes, too many customization due to various requirements, I don't expect Bentley can provide such one neither. If...
View ArticleWiki Page: Change Size-Change Spec Or Other Dialogs Are Frozen And Cannot Be...
Applies To Product(s): AutoPLANT Piping Version(s): V8i Environment: N/A Area: N/A Subarea: N/A Original Author: Derek Cornell, Bentley Technical Support Group Overview In AutoCAD or AutoPLANT,...
View ArticleForum Post: What's the bolt/gasket selection rule at spec break
I'd like know what's the rule for bolt/gasket selection when change pipe spec. And if connected to nozzle, what will happen if nozzle is assigned a different spec or empty. Thanks a lot!
View ArticleWiki Page: Using PXF To Export Lines From One Project To Another [TN]
Applies To Product(s): AutoPLANT Piping Version(s): 08.11.06.30, 08.09.03.30 Environment: N/A Area: N/A Subarea: N/A Original Author: Richard DeLong, Bentley Technical Support Group Overview Sometimes,...
View ArticleForum Post: RE: What's the bolt/gasket selection rule at spec break
Hi Changsong, It queries bolts and gaskets from the spec of mating flange. In case of nozzle, it will query the bolts and gaskets from the spec of flange being placed. Is there any different behavior...
View ArticleWiki Page: How do I manually add a new column to the Database Property Mapping?
Applies To Product(s): Class Editor Version(s): V8i Environment: Windows 7 64-bit Area: Plant Project Tools Subarea: Original Author: Brandon Moberg, Bentley Product Advantage Group Problem Description...
View ArticleForum Post: RE: What's the bolt/gasket selection rule at spec break
1. Spec break case. For example, Spec1 has gasket1/bolt1, spec2 has gasket2/bolt2, which gasket/bolt will be used? Or OPM will list both gasket/bolt, the user can select them? 2. Nozzle case. Do you...
View ArticleForum Post: RE: What's the bolt/gasket selection rule at spec break
In both the cases, whatever spec is active in standard preferences dialog will be used to place gasket/bolt irrespective of the component spec.
View ArticleForum Post: RE: OpenPlant Modler adding custom tank
Thanks a lot ! But now I have a new problem caused by EquipmentDiagrams00.cel . Can you help me and say what is a right way to create this type of cell for equipment (CUBIC TANK) and adding it to...
View ArticleForum Post: Is it possible to filter iso name in OPIM
For example, there are hundreds of pipelines in a i-model, they will list in OPIM. It list the pipelines by Iso Sheet/Area/Service/Unit right now. If I need to extract some pipelines, for example,...
View ArticleForum Post: RE: OpenPlant Modler adding custom tank
You can open this cell file in OpenPlant Modeler and create new model or copy existing model and make the changes accordingly. To create New Model To Copy Existing Model Hope this helps! Regards, Harpreet
View ArticleWiki Page: Olet Section Doesn't Show All Sizes From Catalog in Specification...
Applies To Product(s): OpenPlant Specification Generator Version(s): 08.11.09.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64-bit) Area: Spec Building Subarea: Data Original Author:...
View ArticleWiki Page: OpenPlant Specification Generator
About Specification Generator The Spec Generator is a stand-alone application whose primary function is to generate specifications for use with Bentley's OpenPlant applications. These catalogs and...
View ArticleForum Post: Modifying a custom component after placement
Is there any way to modify a custom component that was created and placed in the model? We have a non-standard component. The user created a custom component and placed it in the model. We later...
View ArticleForum Post: RE: Modifying a custom component after placement
Hello Richard, You can use key-in Drop Element and define the component once again. This way you need not have to define any primitives but you need to assign ports and other data's once again. You can...
View Article