Forum Post: RE: OpenPlant Object enabler for Navisworks
Hi Mark, Sorry, not yet find anything on this. Regards, Rakesh.Saka@mwhglobal.com
View ArticleWiki Page: To Place an Elbow with Trimmed Angle using Intelligent Line Manager
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Component Subarea: Trim Elbow - Intelligent Line Manager...
View ArticleWiki Page: Component - OpenPlant Modeler
Component- OpenPlant Modeler See Index: Add or Remove Fields from Spec Selection Dialog Delete/Replace the Flange Assembly in Open Plant Modeler How are Bolt Lengths Calculated in OpenPlant Modeler...
View ArticleForum Post: Release of Bentley i-model Composition Service for S3D – 08.11.14.24
Hi, I am pleased to announce a new release of Bentley i-model Composition Service for S3D. This is a refresh release from the previously released version 08.11.14.18. It is now available for download...
View ArticleForum Post: OPPID - Replace Deleted Inst Bubble
OPPID When a inline instrument's (control valve, flow element) bubble gets deleted, how do you replace it without replacing the instrument? Thank you
View ArticleWiki Page: How do I manually add a new column to the Database Property Mapping?
Applies To Product(s): Class Editor Version(s): V8i Environment: N\A Area: N\A Subarea: N\A Original Author: Brandon Moberg, Bentley Product Advantage Group In an instance when users want to add new...
View ArticleForum Post: OPM cannot attach Power ProStructures models
Pure MS V8i can open/attach power prostructure dgn files, no problem. But if attach power prostructure dgn files in OPM, it will incur problem. Does anyone know it? The users just want to attach the...
View ArticleForum Post: RE: OPM cannot attach Power ProStructures models
Hi Changsong, Are you getting any error on attaching the files? Meanwhile try installing latest version of ProStructures Object Enabler and see if it solves the issue. Click Here to download the same....
View ArticleForum Post: bolt issue for wafer type connection
Hello All, For wafer type component, there should be a long bolt. I created a wafer type valve in a spec, and I used same spec mdb file in two different workspace. In a workspace the bolt is OK, only...
View ArticleForum Post: RE: OPM cannot attach Power ProStructures models
If your OPM can attach ProStructures models directly after the plug-in installed, It is ok. Sorry I cannot install it. Thanks a lot!
View ArticleForum Post: RE: bolt issue for wafer type connection
Hello Changsong, You can compare project pcf file and see for changes . Also you can compare End preparation type under JOINT class present in schema. Check below wiki for similar discussion on Wafer...
View ArticleForum Post: RE: OPPID - Replace Deleted Inst Bubble
Hi Neil, Please refer below wiki article to place bubble annotation manually on the instruments. If you do not wish to create the tool, you can simply use this Key-In command "pid insert OpenPlant_PID...
View ArticleWiki Page: Annotating Motor Operator Tag with Three Way Control Valves
Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Component Subarea: Data Original Author: Harpreet Singh, Bentley...
View ArticleWiki Page: How to Place Bubble Annotation Manually on Inline Instrument
Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Inline Instruments Subarea: Bubble Annotation Original Author:...
View ArticleFile: Readme for OpenPlant PID V8i SELECTseries 6 Refresh release
Readme file for OpenPlant PID V8i (SELECTseries 6) Refresh release (Version 08.11.11.218) is available for download. Kindly review this file for information on system requirements, licensing, software...
View ArticleForum Post: RE: OPPID - Replace Deleted Inst Bubble
Glad to know that it worked for you :) Regards, Harpreet
View ArticleForum Post: RE: bolt issue for wafer type connection
Thanks for reply. 1. I compared the pcf file, didn't find useful difference. The "OPM_CUSTOM_WAFER_TYPE_END_PREPS" part is same. 2. I checked the End Prep Type, same. 3. It has nothing to do with spec....
View ArticleForum Post: RE: Bolt Length cannot be calculated
The bolt_len is 0 in spec. And bolt_inc is 5. Then OPM will calculate the bolt length and show correct length (for example 85) in the bolt attribute. If one of the flanged end prep is my new end type...
View ArticleWiki Page: To Assign User Defined Fonts in OpenPlant Support Engineering
Applies To Product(s): OpenPlant Support Engineering Version(s): 08.11.11.87 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Project Dashboard Subarea: Fonts Original Author: Rahul Kumar, Bentley...
View Article