Quantcast
Channel: OpenPlant | AutoPLANT
Browsing all 12277 articles
Browse latest View live

Forum Post: RE: OpenPlant Object enabler for Navisworks

Hi Mark, Sorry, not yet find anything on this. Regards, Rakesh.Saka@mwhglobal.com

View Article


Wiki Page: To Place an Elbow with Trimmed Angle using Intelligent Line Manager

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX (SS5) | 08.11.11.XX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Component Subarea: Trim Elbow - Intelligent Line Manager...

View Article


Wiki Page: Component - OpenPlant Modeler

Component- OpenPlant Modeler See Index: Add or Remove Fields from Spec Selection Dialog Delete/Replace the Flange Assembly in Open Plant Modeler How are Bolt Lengths Calculated in OpenPlant Modeler...

View Article

Forum Post: Release of Bentley i-model Composition Service for S3D – 08.11.14.24

Hi, I am pleased to announce a new release of Bentley i-model Composition Service for S3D. This is a refresh release from the previously released version 08.11.14.18. It is now available for download...

View Article

Forum Post: OPPID - Replace Deleted Inst Bubble

OPPID When a inline instrument's (control valve, flow element) bubble gets deleted, how do you replace it without replacing the instrument? Thank you

View Article


Wiki Page: How do I manually add a new column to the Database Property Mapping?

Applies To Product(s): Class Editor Version(s): V8i Environment: N\A Area: N\A Subarea: N\A Original Author: Brandon Moberg, Bentley Product Advantage Group In an instance when users want to add new...

View Article

Forum Post: OPM cannot attach Power ProStructures models

Pure MS V8i can open/attach power prostructure dgn files, no problem. But if attach power prostructure dgn files in OPM, it will incur problem. Does anyone know it? The users just want to attach the...

View Article

Forum Post: RE: OPM cannot attach Power ProStructures models

Hi Changsong, Are you getting any error on attaching the files? Meanwhile try installing latest version of ProStructures Object Enabler and see if it solves the issue. Click Here to download the same....

View Article


Forum Post: bolt issue for wafer type connection

Hello All, For wafer type component, there should be a long bolt. I created a wafer type valve in a spec, and I used same spec mdb file in two different workspace. In a workspace the bolt is OK, only...

View Article


Forum Post: RE: OPM cannot attach Power ProStructures models

If your OPM can attach ProStructures models directly after the plug-in installed, It is ok. Sorry I cannot install it. Thanks a lot!

View Article

Forum Post: RE: bolt issue for wafer type connection

Hello Changsong, You can compare project pcf file and see for changes . Also you can compare End preparation type under JOINT class present in schema. Check below wiki for similar discussion on Wafer...

View Article

Forum Post: RE: OPPID - Replace Deleted Inst Bubble

Hi Neil, Please refer below wiki article to place bubble annotation manually on the instruments. If you do not wish to create the tool, you can simply use this Key-In command "pid insert OpenPlant_PID...

View Article

Wiki Page: Annotating Motor Operator Tag with Three Way Control Valves

Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Component Subarea: Data Original Author: Harpreet Singh, Bentley...

View Article


Wiki Page: How to Place Bubble Annotation Manually on Inline Instrument

Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX (SS5) | 08.11.11.XXX (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Inline Instruments Subarea: Bubble Annotation Original Author:...

View Article

File: Readme for OpenPlant PID V8i SELECTseries 6 Refresh release

Readme file for OpenPlant PID V8i (SELECTseries 6) Refresh release (Version 08.11.11.218) is available for download. Kindly review this file for information on system requirements, licensing, software...

View Article


Forum Post: RE: OPPID - Replace Deleted Inst Bubble

Works perfectly thank you!!!

View Article

Forum Post: RE: OPPID - Replace Deleted Inst Bubble

Glad to know that it worked for you :) Regards, Harpreet

View Article


Forum Post: RE: bolt issue for wafer type connection

Thanks for reply. 1. I compared the pcf file, didn't find useful difference. The "OPM_CUSTOM_WAFER_TYPE_END_PREPS" part is same. 2. I checked the End Prep Type, same. 3. It has nothing to do with spec....

View Article

Forum Post: RE: Bolt Length cannot be calculated

The bolt_len is 0 in spec. And bolt_inc is 5. Then OPM will calculate the bolt length and show correct length (for example 85) in the bolt attribute. If one of the flanged end prep is my new end type...

View Article

Wiki Page: To Assign User Defined Fonts in OpenPlant Support Engineering

Applies To Product(s): OpenPlant Support Engineering Version(s): 08.11.11.87 (SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Project Dashboard Subarea: Fonts Original Author: Rahul Kumar, Bentley...

View Article
Browsing all 12277 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>